Fa   |   Ar   |   En
   an investigation on the accuracy of laboratory measurements of the small-strain soil stiffness  
   
DOR 20.1001.2.9819010854.1398.8.1.114.1
نویسنده jalili javad
منبع كنفرانس بين المللي زلزله شناسي و مهندسي زلزله - 1398 - دوره : 8 - هشتمین کنفرانس زلزله شناسی و مهندسی زلزله - کد همایش: 98190-10854 - صفحه:1 -2
چکیده    Small-strain soil properties are required for a couple of static or mostly dynamic calculations. the frequent laboratory tests to measure soil properties at small strains include resonant-column and piezoelectric bender element test. other element tests may also measure such properties being equipped with transducers capable of detecting fine quantities. toprobe the accuracy of small-strain measurements at the laboratory, a detailed experimental study was conducted on a dummy polyurethane specimen.
کلیدواژه small-strain stiffness ,resonant-column test ,bender element test ,strain gauge
آدرس international institute of earthquake engineering and seismology (iiees), iran
پست الکترونیکی jalili@iiees.ac.ir
 
     
   