Fa   |   Ar   |   En
   A Comparison of Pulsed and Non-Pulsed Conditions on the Drop Sizes in Disc and Doughnut Extraction Column  
   
DOR 20.1001.2.9919199705.1399.11.1.176.1
نویسنده - - ,- - ,- -
منبع كنگره مهندسي شيمي - 1399 - دوره : 11 - یازدهمین کنگره بین المللی مهندسی شیمی - کد همایش: 99191-99705
چکیده    The application of disc and doughnut extraction columns has been increased in different industries due to their advantages# the column conditions affect the operating streams, and the droplet diameter is an important parameter that changes with the pulse and non-pulse conditions in these columns# the performance of the column with the water-toluene system showed that under non-pulse conditions, the dispersed phase velocity affects the droplet sizes inside the column# the decrease in droplet size occurs with the increment in the dispersed phase velocity in non-pulse conditions# but continuous phase velocity does not affect the drop sizes# in pulsed conditions, the amplitude of variations in different pulses is the most critical factor in the type of regime and droplet size#
کلیدواژه Non-Pulsed Condition ,Pulse Intensity ,Disc And Doughnut Column ,Droplet Size ,Operating Parameters
آدرس Nuclear Science And Technology Research Institute, Iran, Nuclear Science And Technology Research Institute, Iran, Nuclear Science And Technology Research Institute, Iran
 
     
   