Optimizing An A2o Bioreactor Design, Comparing Wwt Design Calculation Methods For Bnr Removal
|
|
|
DOR
|
20.1001.2.9919199705.1399.11.1.28.3
|
نویسنده
|
- - ,- -
|
منبع
|
كنگره مهندسي شيمي - 1399 - دوره : 11 - یازدهمین کنگره بین المللی مهندسی شیمی - کد همایش: 99191-99705
|
|
|
چکیده
|
Activated sludge models have been widely used for the design, control and optimization of activated sludge plants operated for organic carbon and nutrient removal# hovewer, appropriate use of those models essentially requires (1) precise influent-wastewater characterization (2) wise use of calibration methodology for activated sludge models and as a result: (3) interpretation of results obtained from modeling study# in the first part of the study, the wastewater characterization was determined at the operating conditions and the percentil values were calculated for the design# then, the plant was designed with different (atv-dvwk 131-e, uct and werf) design methods and the results were compared# denitrification was happened almost equal in all methods# south african method had a better rate of dephosphorylation# finally, werf was a better method for reduction in volume, space and energy consumption#
|
کلیدواژه
|
Wastewater Treatment ,Design Methods ,A2o ,Anaerobic ,Anoxic ,Aerobic
|
آدرس
|
Tarbiat Modares University, Iran, Tarbiat Modares University, Iran
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|