>
Fa   |   Ar   |   En
   Biomechanical Effects of Platform Switching in Two Different Implant Systems: A Three-Dimensional Finite Element Analysis  
   
نویسنده Sahabi Mahasti ,Adibrad Mehdi ,Mirhashemi Fatemeh Sadat ,Habibzadeh Sareh
منبع Frontiers In Dentistry - 2013 - دوره : 10 - شماره : 4 - صفحه:338 -350
چکیده    Objectives: the purpose of this study was to determine the influence of platform switch-ing on stress distribution of two different implant systems using three-dimensional (3d) finite element models.materials and methods: six 3d finite element models were created to replicate two dif-ferent implant systems with peri-implant bone tissue, in which six different implant-abutment configurations were represented: model xive-a: 3.8-mm-diameter implant and 3.8-mm-diameter abutment; model xive-b (platform-switching model): 4.5-mm-diameter implant and 3.8-mm-diameter abutment; model xive-c: 4.5-mm-diameter implant and 4.5-mm-diameter abutment; model 3i-a: 4.0-mm-diameter implant and 4.1-mm-diameter abutment; model 3i-b (platform-switching model): 5.0-mm-diameter implant and 4.1-mm-diameter abutment; model 3i-c: 5.0-mm-diameter implant and 5.0-mm-diameter abutment. vertical and oblique loads of 100 were applied to all models.results: while the pattern of stress distribution was similar for both loading situations, oblique loading resulted in higher intensity and greater distribution of stress than axial loading in both cortical bone and implant-abutment- interface. stress distribution at peri-implant bone was almost identical with similar magnitudes for all six models. in both im-plant systems, platform-switching models demonstrated lower maximum von mises stress in cortical bone than conventional models. however, in both implant systems and under both loading situations, platform-switching models showed higher stresses at the implant-abutment interface than conventional models.conclusion: in both implant systems, platform switching design reduced the stress con-centration in the crestal bone and shifted it towards the area of implant-abutment interface.
کلیدواژه Dental Implants ,Abutment Design ,Finite Element Analysis ,Alveolar Bone Loss
آدرس Shahid Beheshti University Of Medical Sciences, School Of Dentistry, Research Institute Of Dental Sciences, Dental Research Center, Department Of Prosthodontics, ایران, Isfahan University Of Medical Sciences, School Of Dentistry, Department Of Periodontology, ایران, Shahid Beheshti University Of Medical Sciences, Research Institute Of Dental Sciences, Dental Research Center, ایران. Ferdowsi University Of Mashhad, ایران, Tehran University Of Medical Sciences Tums, Dental School, Department Of Prosthodontist, ایران
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved