|
|
Effect of Abutment Taper on the Fracture Resistance of all-Ceramic Three-unit Bridges
|
|
|
|
|
نویسنده
|
Gerami-Panah F. ,Jalali H. ,Sedighpour L.
|
منبع
|
frontiers in dentistry - 2005 - دوره : 2 - شماره : 4 - صفحه:159 -168
|
چکیده
|
Statement of problem: the connector area is the weakest zone of an all-ceramic fixed partial denture (fpd), where most catastrophic failures of the prostheses tend to occur. purpose: the aim of the present study was to assess the effect of the convergence angle of abutments on the fracture resistance of three-unit fixed partial dentures made of ipsempress2. materials and methods: forty extracted human premolars and molars were used to reproduce twenty, 3-unit fixed partial dentures, for the replacement of second premolars. all teeth were prepared according to the guidelines outlined for all-ceramic crowns and bridges, except for the convergence angles of the abutments. the specimens were randomly divided into two groups of 10, with total occlusal convergence angles of 12° and 22°. fixed partial dentures with a uniform thickness of 0.8 mm were fabricated using ips-empress2 and were bonded to the corresponding models. connector dimensions were set to 4 mm height and 4mm width. the radius of curvature at the gingival embrasure was carved to 0.9 mm. all specimens were exposed to 10,000 preloading cycles and a load of 40 n at a frequency of 1.3 hz in a standardized testing machine at a cross head speed of 1mm/min. student t-test was performed to detect any difference in the mean fracture resistance between the two groups (α = 0.05). results: mean failure loads (and standard deviations) of the 12° and 22° groups were 1009.12 n (208.05) and 1182.72 n (144.67), respectively. statistical analysis revealed a significant difference (p <0.04) between the mean failure loads of the two groups. most fractures occurred through the connectors. conclusion: the mean failure loads of the investigated fixed partial dentures were higher in the abutments with 22° taper as compared to those with a taper of 12°.
|
کلیدواژه
|
Fixed partial denture; Fracture resistance; Dental ceramics ,Lithium disilicate; All-ceramic; Glass ceramic; IPS-Empress 2
|
آدرس
|
tehran university of medical sciences tums, Faculty of Dentistry, Dental Research Center, Department of Prosthodontics, ایران, tehran university of medical sciences tums, Faculty of Dentistry, Department of Prosthodontics, ایران, tehran university of medical sciences tums, Faculty of Dentistry, Department of Prosthodontics, ایران
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|