Laminar Flow Heat Transfer of A Pseudoplastic Fluid Through A Double Pipe Heat Exchanger
|
|
|
|
|
نویسنده
|
Moradi M. ,Etemad S. Gh. ,Moheb A.
|
منبع
|
Iranian Journal Of Chemical Engineering - 2006 - دوره : 3 - شماره : 2 - صفحه:13 -19
|
|
|
چکیده
|
An experimental study was carried out to obtain the mean convective heat transfer coefficient of aqueous carboximethyl cellulose (cmc) solutions in double-pipe heat exchangers. co-current and counter- flows were considered in the investigation. from the experimental data a nusselt number was calculated for a wide range of graetz number, reynolds number, and cmc concentrations. increasing the graetz and reynolds numbers promote the heat transfer and variation of cmc concentration has a noticeable effect on the nusselt number.
|
کلیدواژه
|
Non-Newtonian Fluids ,Double-Pipe Heat Exchanger ,Nusselt Number ,Greatz Number ,Experimental
|
آدرس
|
Isfahan University Of Technology, Department Of Chemical Engineering, ایران, Isfahan University Of Technology, Department Of Chemical Engineering, ایران, Isfahan University Of Technology, Department Of Chemical Engineering, ایران
|
|
|
|
|
|
|
|
|
|
|
|
|
|