Fa   |   Ar   |   En
   Parasitic Effect of Tube Wall Longitudinal Heat Conduction on Cryogenic Gas Temperature  
   
نویسنده Saberimoghaddam A. ,Bahri Rasht Abadi M. M.
منبع Iranian Journal Of Chemical Engineering - 2017 - دوره : 14 - شماره : 1 - صفحه:15 -25
چکیده    Longitudinal heat conduction is an important parameter in the cryogenic science, especially in cryogenic heat exchangers. in the present work, the parasitic effect of tube wall longitudinal heat conduction on temperature measurement has been studied in cryogenic laminar hydrogen flow. the effects of various parameters such as wall cold end temperature, wall thermal conductivity, gas volumetric flow, and tube wall thickness have been investigated by finite element method. the model was also validated versus the data obtained from experiments. the simulations showed that temperature drop occurs in gas flow at the end section of tube length. this section is independent of tube cold end temperature and leads to large temperature measurement error in laminar flows. results showed that a few millimeters change in temperature sensor position results in measurement errors up to 80 %. the higher tube wall thermal conductivity and tube wall thickness result in higher parasitic effects of longitudinal heat conduction.
کلیدواژه Longitudinal Heat Conduction ,Cryogenic ,Heat Exchanger ,Parasitic Effect
آدرس Malek Ashtar University Of Technology (Mut), Faculty Of Chemical Engineering, Department Of Chemistry And Chemical Engineering, ایران, Malek Ashtar University Of Technology (Mut), Faculty Of Chemical Engineering, Department Of Chemistry And Chemical Engineering, ایران
پست الکترونیکی mmbahri@mut.ac.ir
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved