Fa   |   Ar   |   En
   Comparison of Keratometric Values Using Javal Keratometer, Oculus Pentacam, and Orbscan II  
   
نویسنده Hashemi Hassan ,Yekta AbbasAli ,Ostadimoghaddam Hadi ,Norouzirad Reza ,Khabazkhoob Mehdi
منبع journal of current ophthalmology - 2014 - دوره : 26 - شماره : 1 - صفحه:3 -10
چکیده    Purpose: to compare orbscan ii and pentacam keratometry readings in terms of their agreement with a manual javal type keratometer. methods: in this retrospective study, records of patients who had refractive surgery were reviewed. we extracted data of 765 eyes which had keratometry with the javal keratometer; of these, 577 had orbscan ii and 200 eyes had pentacam acquisitions. minimum (min-k) and maximum (max-k) keratometry readings and keratometric astigmatism with the latter two devices were compared with javal. results: correlation coefficients for javal and orbscan ii in measuring min-k and max-k were r=0.916 and r=0.913, respectively (p<0.001). the 95% limits of agreement (loa) between javal and orbscan ii was 1.17-1.20 d for min-k and 1.22-1.24 d for max-k. the coefficients for pentacam and javal min-k and max-k readings were very high (r=0.943 and r=0.962). the 95% loa between pentacam and javal in measuring min-k and max-k were 0.51-0.99d and 0.72-0.99d, respectively. the correlation between pentacam and javal measurements of keratometric astigmatism was stronger than that for orbscan ii and javal (r=0.973 and r=0.800); the 95% loa was 0.55-0.76d for pentacam and javal, and 1.14-1.19d for orbscan ii and javal. conclusion: according to this research, orbscan ii and pentacam had high correlation and agreement with javal-keratometer in determining keratometric values. nevertheless, the results obtained from pentacam showed better agreement and stronger correlation with javal as compared with orbscan ii. it seems that pentacam is a suitable substitute for javal to perform keratometry in normal eyes.
کلیدواژه Keratometry ,Orbscan II ,Pentacam ,Javal-keratometer
آدرس Noor Eye Hospital, Noor Ophthalmology Research Center, ایران, mashhad university of medical sciences, School of Paramedical Sciences, Refractive Errors Research Center, Department of Optometry, ایران, mashhad university of medical sciences, School of Paramedical Sciences, Vision Sciences Research Center, Department of Optometry, ایران, Dezful University of Medical Sciences, ایران, shahid beheshti university of medical sciences, Faculty of Health, Department of Epidemiology, ایران
پست الکترونیکی khabazkhoob@yahoo.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved