>
Fa   |   Ar   |   En
   Evaluation of Corneal Biomechanical Properties following Scleral Buckling Using the Ocular Response Analyzer  
   
نویسنده Riazi Esfahani Mohammad ,Jafarzadehpur Ebrahim ,Hashemi Hassan ,Ghaffari Elina
منبع journal of current ophthalmology - 2013 - دوره : 25 - شماره : 2 - صفحه:151 -154
چکیده    Purpose: to evaluate corneal visco-elasticity and intraocular pressure (iop) changes measured by an ocular response analyzer (ora) after scleral buckling. methods: fifty-six eyes with history of scleral buckling surgery three months ago were included in the study. corneal hysteresis (ch), corneal resistance factor (crf), corneal-compensated iop (iopcc) and goldmann-correlated iop (iopg) were measured by ora 3 month postoperatively. in each group, unoperated (normal) eye was the control eye and operated eye was the case eye. results: twenty-seven eyes underwent buckling with encircling elements (group 1) and 29 eyes with segmental sponge (group 2). the mean (±sd) crf in group 1 was 8.74±2.05 in operated eyes and 9.19±1.96 in control contralateral eyes, with no significant difference between them (p=0.412). in group 2 the mean (±sd) crf was 8.14±1.95 in contralateral eyes and 9.38±2.1 in control eyes and the difference was statistically significant (p=0.024). in group 1 there was no significant difference between mean ch of cases and controls (p=0.286), but statistically significant difference between mean ch of cases and controls in group 2 (p=0.044). there were no significant differences between iopg and iopcc of cases and controls in two groups. conclusion: mean crf and ch measurements were significantly lower after scleral buckling with segmental sponge, but no significant change in encircling procedure was observed. also no significant change in iopg and iopcc in any kind of scleral buckling technique occurred postoperatively. it seems that hysteresis and crf may measure different biomechanical aspects of ocular rigidity and are likely to be useful additional measurements in the assessment of ocular rigidity when measuring iop.
کلیدواژه Corneal Visco-Elasticity ,Intraocular Pressure ,Ocular Response Analyzer ,Scleral Buckling ,Encircling Band ,Segmented Buckle
آدرس Noor Eye Hospital, Noor Ophthalmology Research Center, ایران. tehran university of medical sciences tums, Farabi Eye Hospital,Eye Research Center, ایران, Noor Eye Hospital, Noor Ophthalmology Research Center, ایران, Noor Eye Hospital, Noor Ophthalmology Research Center, ایران. tehran university of medical sciences tums, Farabi Eye Hospital,Eye Research Center, ایران, tehran university of medical sciences tums, Farabi Eye Hospital,Eye Research Center, ایران. Noor Eye Hospital, Noor Ophthalmology Research Center, ایران
پست الکترونیکی heidarian_sh@yahoo.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved