Corneal hysteresis and corneal resistance factor in pellucid marginal degeneration
|
|
|
|
|
نویسنده
|
sedaghat mohamad reza ,ostadi-moghadam hadi ,jabbarvand mahmoud ,askarizadeh farshad ,momeni-moghaddam hamed ,narooie-noori foroozan
|
منبع
|
journal of current ophthalmology - 2018 - دوره : 30 - شماره : 1 - صفحه:42 -47
|
چکیده
|
Purpose: to evaluate and compare corneal hysteresis (ch) and corneal resistance factor (crf) in pellucid marginal degeneration (pmd), keratoconus (kcn), and normal eyes using the ocular response analyzer (ora). methods: in this retrospective study, corneal biomechanical parameters were measured in patients with pmd (n = 102) and kcn (n = 202) and normal subjects (n = 208) using the ora. data, including full patient history as well as the results of refraction, slit-lamp biomicroscopy, pentacam hr (oculus), and ora (reichert; buffalo, new york, usa), were collected from medical records. also, the data of only one eye per individual were selected for the analysis. the inclusion criteria for pmd and kcn groups were a reliable diagnosis of these ectatic disorders based on the clinical and corneal tomographic findings. ch, crf, ch-crf, intraocular pressure (iop) measurements were assessed for each subject. data were analyzed with spss and medcalc using the anova, pearson correlation, and receiver operating characteristic (roc) curve analysis. results: the mean ch was 8.91 mmhg ± 1.05 [standard deviation (sd)], 8.43 ± 0.78, and 10.89 ± 1.08 in the pmd, kcn, and normal group, respectively. also, the mean crf was 8.21 ± 1.35, 7.19 ± 1.11, and 10.69 ± 1.41 in the pmd, kcn, and normal group, respectively. anova showed differences in the mean ch, crf, and ch-crf between three groups (p < 0.001). also, roc curve analysis showed the cut-off points ≤9.5, ≤9.5, and >1.3 mmhg for ch, crf, and ch-crf in the pmd group, respectively. for biomechanical parameters in pmd eyes, crf had the highest sensitivity (75.49%) while the greatest area under the roc curve (auc) was seen for ch (0.903). moreover, central corneal thickness (cct) showed no correlation with ch (p = 0.30, r = -0.104) or crf (p = 0.75, r = 0.033) in the pmd group. conclusions: this study presented the values of corneal biomechanics for pmd using the ora. the results of the orawere markedly different between pmd, kcn, and normal eyes.
|
کلیدواژه
|
Pellucid marginal degeneration; Corneal biomechanics; Corneal hysteresis; Corneal resistance factor; Keratoconus
|
آدرس
|
mashhad university of medical sciences, cornea research center, khatam-al-anbia hospital, Iran, mashhad university of medical sciences, school of paramedical sciences, refractive errors research center, department of optometry, iran, tehran university of medical sciences, ophthalmology research center, farabi eye hospital, Iran, mashhad university of medical sciences, refractive errors research center, school of paramedical sciences, department of optometry, Iran, mashhad university of medical sciences, refractive errors research center, school of paramedical sciences, department of optometry, Iran, mashhad university of medical sciences, refractive errors research center, school of paramedical sciences, department of optometry, Iran
|
پست الکترونیکی
|
f.narooie.opt@gmail.com
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|