Fa   |   Ar   |   En
   Evaluation of Subconjunctival Oculusgen Implantation as an Adjunct to Trabeculectomy  
   
نویسنده Nilforushan Naveed ,Yadgari Maryam ,Ghasemi Falavarjani Khalil ,Ehteshami Afshar Arash
منبع journal of current ophthalmology - 2010 - دوره : 22 - شماره : 2 - صفحه:55 -62
چکیده    Purpose: to evaluate the efficacy and safety of subconjunctival oculusgen implantation when used during trabeculectomymethods: in this prospective, nonrandomized, interventional case series, 10 eyes of 10 patients with medically uncontrolled open angle glaucoma were enrolled. conventional fornix based trabeculectomy with implantation of subconjunctival biodegradable collagen implant (oculusgen) was performed in all patients. the preoperative best corrected visual acuity (bcva), intraocular pressure (iop) measurement and numbers of antiglaucoma medication were recorded. there were 7 postoperative follow-up visits within 6 months after surgery. after 6 months, follow-up visits were continued every 2-3 months. at each visit, the examination included measurements of bcva and iop, slit-lamp biomicroscopy, assessment of cell and flare, bleb evaluation and funduscopy. any complications were recorded at the end of each examination. data analysis was performed using spss software version 15.results: mean duration of follow-up was 11.9 months (range 6-26 months). mean preoperative iop was 19.3 mmhg (range 12-25 mmhg) with 2.9 number of iop lowering medications (range 2-4) and mean postoperative iop was 15.3 mmhg (range 10-24) at month 6 (p=0.028) and 14.7 (range 10-20) at last visit (p=0.016). mean iop lowering medications and iop reduction after 180 days were 0.4 (range 0-3) (p=0.000) and 4.2 mmhg respectively. mean iop lowering medications and iop reduction at last visit were 0.7 (range 0-3) (p=0.000) and 4.8 mmhg. overall success at last follow-up was 80%. none of the patients experienced systemic or ocular complication related to oculusgen.conclusion: trabeculectomy with implantation of oculusgen is a safe and effective surgical method in patients with open angle glaucoma, but longer duration of follow-up in larger number of patients is needed.
کلیدواژه Glaucoma ,Oculusgen ,Trabeculectomy ,Mitomycin C
آدرس iran university of medical sciences, Rassoul Akram Hospital, Eye Research Center, ایران, iran university of medical sciences, Rassoul Akram Hospital, Eye Research Center, ایران, iran university of medical sciences, Rassoul Akram Hospital, Eye Research Center, ایران, iran university of medical sciences, Rassoul Akram Hospital, Eye Research Center, ایران
پست الکترونیکی naveednil@yahoo.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved