Fa   |   Ar   |   En
   Heat Transfer and Friction Factor in a Tube Equipped with U-cut Twisted Tape Insert  
   
نویسنده Murugesan P. ,Mayilsamy K. ,Suresh S.
منبع jordan journal of mechanical and industrial engineering - 2011 - دوره : 5 - شماره : 6 - صفحه:559 -565
چکیده    Experimental investigation of heat transfer and friction factor characteristics of circular tube fitted with plain twisted tapes (ptt) and u–cut twisted tapes (utt) with twist ratios y = 2.0, 4. 4 and 6.0 were studied. the experimental data obtained from plain tube and ptt were verified with the standard correlation to ensure the validation of experimental results. the experimental results reveal that heat transfer rate, friction factor and thermal enhancement factor in the tube equipped with utt significantly higher than those in the tube fitted with ptt and plain tube. the additional disturbance and secondary flow in the vicinity of the tube wall generated by the utt compared to that induced by the ptt is referred as the reason for the enhancement. subsequently an empirical correlation is also formulated to match with experimental results with ± 6% and ± 5%, variation respectively for nusselt number and friction factor.
کلیدواژه heat transfer enhancement; friction factor; plain twisted tape; U –cut twisted tape; secondary flo
آدرس K.S. Rangasamy College of Technology, Department of Mechanical Engineering, India, Institute of Road and Transport Technology, Department of Mechanical Engineering, India, National Institute of Technology, Department of Mechanical Engineering, India
پست الکترونیکی pmksrct@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center