A Correlation for the Prediction of Nucleate Pool Boiling Performance of Pure Liquids from Enhanced Tubes
|
|
|
|
|
نویسنده
|
Tarrad Ali H.
|
منبع
|
jordan journal of mechanical and industrial engineering - 2011 - دوره : 5 - شماره : 2 - صفحه:139 -144
|
چکیده
|
This investigation is devoted to study the enhancement factor of single enhanced tubes boiling pure liquids. two surfaces of the integral machined structure; gewa-t and low finned, tubes were considered. a new correlation for the estimation of the heat transfer coefficient in the nucleate region was developed based on the buckingham (ð) theorem for these tubes. the enhancement factor is a strong function of the fin shape of the enhanced surface structure and boiling liquids physical properties. five liquids boiling at atmospheric pressure were considered, r-113, n-pentane, ethanol, water and r-11, for a heat flux in the range between (10) and (50) kw/m2. the total mean absolute errors of the enhancement factors were (6%) and (9%) for the low finned and gewa-t surfaces respectively. the present correlation showed a good agreement with the available experimental data in the literatures for the nucleate pool boiling heat transfer coefficient. it correlated the available data with a corresponding total mean absolute errors were (9.5%) and (13.5 %) for the low finned and gewa-t surfaces respectively.
|
کلیدواژه
|
Nucleate Boiling; Performance; Enhancement Factor; Correlation; Machined Tube
|
آدرس
|
Al-Mustansiriya University, College of Engineering, Department of Mechanical Engineering, Iraq
|
پست الکترونیکی
|
dr.alitarrad@yahoo.com
|
|
|
|
|
|
|
|
|
|
|
|