   cop/exergy analysis of a heat pump coupled with scroll compressor systems at different wintry ambient temperatures  
   
نویسنده norouzi mahdi ,ghazikhani mohsen
منبع تبديل انرژي - 1403 - دوره : 11 - شماره : 3 - صفحه:91 -103
چکیده    In this work, the cop/exergy analysis of a heat pump system coupled with a scroll compressor (hpscsc) is investigated. the experimental data was used to analyse the energy/exergy of hpscsc at different relative intermediate pressure (rip) and wintry temperature to make clear the optimum operating condition based on more cop and extra capability. moreover, an energy input capacity (eic) was defined to suggest the optimum operating of the system. the investigation of irreversibility in the components of the heat pump shows that the most important losses are generated in the compressor (65-80%) and the condenser (12-15%).also, the results confirm that even at very low ambient temperatures (-15oc) -where the cop drops-, the use of less rip leads to an acceptable eic and improvement in cop. the results further indicated that when the rip exceeds 1.2, the energy transfer from the condenser remains relatively constant across various winery temperatures. furthermore, in this study, a relation for the optimum rip against wintry ambient temperature for an acceptable eic and higher cop has been presented, which falls between 1.1 and 1.5.
کلیدواژه heat pump coupled with scroll compressor systems ,wintry ambient temperatures ,exergy analysis ,cop ,relative intermediate pressure ,heat pump coupled with scroll compressor systems ,wintry ambient temperatures ,exergy analysis ,cop ,relative intermediate pressure
آدرس larestan university, department of mechanical engineering, iran, ferdowsi university of mashhad, school of engineering, department of mechanical engineering, iran
پست الکترونیکی ghazikhani@um.ac.ir
 
   cop/exergy analysis of a heat pump coupled with scroll compressor systems at different wintry ambient temperatures  
   
Authors
Abstract    in this work, the cop/exergy analysis of a heat pump system coupled with a scroll compressor (hpscsc) is investigated. the experimental data was used to analyse the energy/exergy of hpscsc at different relative intermediate pressure (rip) and wintry temperature to make clear the optimum operating condition based on more cop and extra capability. moreover, an energy input capacity (eic) was defined to suggest the optimum operating of the system. the investigation of irreversibility in the components of the heat pump shows that the most important losses are generated in the compressor (65-80%) and the condenser (12-15%).also, the results confirm that even at very low ambient temperatures (-15oc) -where the cop drops-, the use of less rip leads to an acceptable eic and improvement in cop. the results further indicated that when the rip exceeds 1.2, the energy transfer from the condenser remains relatively constant across various winery temperatures. furthermore, in this study, a relation for the optimum rip against wintry ambient temperature for an acceptable eic and higher cop has been presented, which falls between 1.1 and 1.5.
Keywords heat pump coupled with scroll compressor systems ,wintry ambient temperatures ,exergy analysis ,cop ,relative intermediate pressure ,heat pump coupled with scroll compressor systems ,wintry ambient temperatures ,exergy analysis ,cop ,relative intermediate pressure
 
 