>
Fa   |   Ar   |   En
   Analysis of Quadriceps Muscles Force and Activity of A 3-Dimensional Musculoskeletal Model  
   
نویسنده Farahmand Farzam ,Hosseini Hossein ,Seifi Mohammad Mehdi
منبع Journal Of Advanced Sport Technology - 2018 - دوره : 2 - شماره : 1 - صفحه:7 -15
چکیده    The purpose of this study was to determine the force of each component of the quadriceps muscles groupin different exercises and to determine the activity ratio of vastus medialis to vastus lateralis. for thispurpose, a 3-d model of the whole body was formed in the anybody modeling system software. thismodel that had muscle only in the legs was sitting on the chair and was performed knee extension.muscular modeling in this study was achieved by using a simple model of the muscles. after creating anduploading model in the software, inverse dynamic analysis carried out, and the force and activity of eachquadriceps muscle component was obtained. the model was tested in three different conditions: (1) notloading, (2) static training with maximum loading, (3) normal loading. then the force and activity of eachquadriceps muscles were examined in gait test. to do this, walking in anybody model was used. in eachof these conditions, the force of each quadriceps muscle component and activity ratio of vastus medialisto vastus lateralis was calculated. according to the results, the rectus femoris muscle in not loading modehad the highest value (28%) in creating force. in the static, normal loading and walking conditions,vastus lateralis had the highest value in creating force that were 38%, 42% and 40%, respectively. theactivity ratio of the vastus medialis to vastus lateralis in static training, normal loading and gait conditionswere 0.92, 0.85 and 0.87 respectively which in static training had the highest value. the results showedthat the force and activity charts of the vastus medialis, vastus lateralis and vastus intermedius hadexactly similar pattern and they were different from the force and activity charts of rectus femoris muscle.in total, it seems that the results are acceptable in some analysis and are not in accordance with previousresults in some others (i.e. not loading condition). therefore, it is necessary to verify and assess theoutputs after modeling in this software.
کلیدواژه Anybody Software ,Quadriceps Muscles ,Knee Joint ,Modeling
آدرس Sharif University Of Technology, School Of Mechanical Engineering, Iran, University Of Guilan, Faculty Of Physical Education And Sport Sciences, Iran, Sharif University Of Technology, Iran
پست الکترونیکی edu.manag@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved