>
Fa   |   Ar   |   En
   determining the concentration of particulate matters and microbiological quality of indoor air in intensive care units of kashan hospital, iran  
   
نویسنده vahidmoghadam razieh ,mirzaei nezam ,mousavi gholamabbas ,nazari-alam ali ,nazeri mehdi ,gholipour sahar ,dehghani rouhullah ,akbari marzieh ,miranzadeh mohammad bagher
منبع journal of environmental health and sustainable development - 2023 - دوره : 8 - شماره : 2 - صفحه:1975 -1987
چکیده    Introduction: maintaining hospital air quality is very important, especially in intensive care units (icus), where patients undergo invasive procedures. therefore, the present study was conducted with the aim of determining the relationship between particulate matters (pms) and bioaerosols in pediatric icu (picu), neonatal icu (nicu), and icu open heart (icu oh) of shahid beheshti hospital in kashan. materials and methods: this cross-sectional study was conducted for six consecutive months, i.e., autumn and winter of 2021. pm samples were taken using a grimm dust monitor and microbial samples were taken using a quick take 30 sampler. kolmogorov-smirnov test was used for analysis and then anova and lsd were used for further tests. results: the maximum and minimum pm10 concentrations in the picu and icu oh were 59.19 and 9.71 μg/m³, respectively; and the maximum and minimum pm2.5 concentrations were 20.23 μg/m3 in the nicu and 4.69 μg/m³ in picu. the mean pm concentration and the number of bacterial and fungal colonies were consistent with the who and epa guidelines. gram-positive staphylococcus were the most abundant bacteria (90.96%). the most abundant fungi were aspergillus (54.23%), penicillium (15.64%), and cladosperium (12.17%) species. there was also no significant relationship between pms and bioaerosols. conclusion: the mean concentrations of pms and bioaerosols match with the guidelines, which can be attributed to more observance of health protocols and restrictions on the movement of people into icus due to the covid-19 outbreak.
کلیدواژه air pollution ,indoor ,hospitals ,particulate matter ,kashan city
آدرس kashan university of medical sciences, faculty of health, department of environmental health engineering, iran, kashan university of medical sciences, faculty of health, social determinants of health (sdh) research center, department of environmental health engineering, iran, kashan university of medical sciences, faculty of health, department of biostatistics and epidemiology, iran, kashan university of medical sciences, infection diseases research center, iran, kashan university of medical sciences, faculty of medicine, department of parasitology and mycology, iran, kashan university of medical sciences, faculty of health, department of environmental health engineering, iran, kashan university of medical sciences, faculty of health, social determinants of health (sdh) research center, department of environmental health engineering, iran, kashan university of medical sciences, faculty of health, department of environmental health engineering, iran, kashan university of medical sciences, faculty of health, social determinants of health (sdh) research center, department of environmental health engineering, iran
پست الکترونیکی miranzadehm@ymail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved