Fa   |   Ar   |   En
   orthopedic screw penetration into the bladder following femoral neck internal fixation: a case report  
   
نویسنده gooran shahram ,guitynavard fateme ,fakhr-yasseri alimohammad ,dehghaniathar reza
منبع case reports in clinical practice - 2016 - دوره : 1 - شماره : 2 - صفحه:31 -33
چکیده    Although the presence of intravesical foreign body is not a rare finding, orthopedic screw penetration into the urinary bladder as a complication of the internal fixation of femoral neck fractures is extremely rare. we describe an 83-year-old man experiencing spontaneous penetration of a cannulated screw into the urinary bladder neck, 16 years after the internal fixation surgery for his femoral neck fracture
کلیدواژه intravesical foreign body ,orthopedic screws ,internal fixation ,femoral neck fracture
آدرس tehran university of medical sciences, sina hospital, urology research center, ایران, tehran university of medical sciences, sina hospital, urology research center, ایران, tehran university of medical sciences, sina hospital, urology research center, ایران, tehran university of medical sciences, sina hospital, urology research center, ایران