|
|
|
|
Evaluation of a new supraglottic airway device in ambulatory surgery: the i-gel® [Evaluation d’un nouveau dispositif de contrôle des voies aériennes dans la chirurgie ambulatoire: Le i-gel®]
|
|
|
|
|
|
|
|
نویسنده
|
jaoua h. ,djaziri l. ,bousselmi j. ,belhouane h. ,skander r. ,ben maamer a. ,cherif a. ,ben fadhel k.
|
|
منبع
|
tunisie médicale - 2014 - دوره : 92 - شماره : 4 - صفحه:239 -244
|
|
چکیده
|
Background: the i-gel® is a new single-use supraglottic airwaydevice with a non-inflatable cuff. it is composed of a thermoplasticelastomer and a soft gel-like cuff that adapts to the hypopharyngealanatomy. its tube is profiled to facilitate and stabilize its insertion.aim: the aim of our study is to state the efficiency and the place ofi-gel® in airway management in adult anaesthetic practice.methods: one hundred patients,asa i-ii,scheduled for shortdurationelective surgery under general anaesthesia were included inthis prospective study. patients with neck pathology,previous oranticipated airway problems,increased risk of regurgitation oraspiration,asa iii and above and undergoing emergency surgerywere not included in the study. we collected the following data:adequacy of the size recommended to the patient,ease in insertingthe i-gel®,leak fraction,gastric leak,complications during insertionand removal,ease in inserting the gastric tube,haemodynamic andventilatory parameters,stability during patient movement andsatisfaction of the anaesthetists.results: the success rate of insertion and the use of the i-gel wasrespectively 99% and 96%. the device was inserted at the firstattempt in 92% of cases. the introduction of the i-gel® was ratedeasy in 99% of cases taking a median of 13 seconds. complicationsof insertion were restricted to coughing in 5 patients and hiccups in7 patients. there were no significant increase in heart rate and meanarterial blood pressure compared to pre-insertion values. an audibleleak was recorded in 14.6% of cases. the need for additionalmanoeuvres was less than or equal to 2 in 96.9% of patients. themean of the recorded peak airway pressure values was 18 cmh2o.after a fibreoptic exam via the airway tube,the glottis wascompletely seen in 74% of cases and partially seen in 14.6%. twocases of gastric inflation were recorded. there was no case ofregurgitation or hypoxemic episode during this trial. post-operativelysore-throat was reported by one patient in recovery. after i-gelwithdrawal,trace of blood was observed in 5 devices. one case ofdental trauma was noted. 95% of the anaesthetists were satisfied withthe use of the i-gel in their pratice.conclusion: this study showed that i-gel® can be used safely andeffectively in patients undergoing short-duration elective surgerybecause the i-gel® has a very good insertion success rate and fewcomplications. the fibreoptic position of the device was correct andthe ventilation was highly effective. these elements must be corroborated in larger series. © 2015,maison du medicine. all right reserved.
|
|
کلیدواژه
|
Airways; Ambulatory surgery; General anaesthesia; Laryngeal mask airway; Supraglottic device
|
|
آدرس
|
service d’anesthésie réanimation,hôpital habib thameur, Tunisia, service d’anesthésie réanimation,hôpital habib thameur, Tunisia, service d’anesthésie réanimation,hôpital habib thameur, Tunisia, service d’anesthésie réanimation,hôpital habib thameur, Tunisia, service d’anesthésie réanimation,hôpital habib thameur, Tunisia, service de chirurgie viscérale,hôpital habib thameur, Tunisia, service de chirurgie viscérale,hôpital habib thameur, Tunisia, service d’anesthésie réanimation,hôpital habib thameur, Tunisia
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|