   To detect the outcome of proximal humerus fractures treated with a locking proximal humerus plate  
   
نویسنده ahmed n. ,khan t.a. ,anwar m.a. ,ali a.
منبع pakistan journal of medical and health sciences - 2015 - دوره : 9 - شماره : 1 - صفحه:281 -285
چکیده    Aim: to evaluate the safety,usefulness,and practical outcome of the locked proximal humerus plate (lphp) to treat proximal humerus fractures. setting: patel hospital karachi,indus hospital karachi and civil hospital karachi. methods: over a 08 month period,64 consecutive patients were treated with a lphp for an unstable or displaced proximal humerus fracture. demographic data,trauma mechanisms,surgical approaches,and postoperative complications were collected from medical records. fracture classification according to the neer classification,radiographic head-shaft angle,and screw tip-articular surface distance in true anteroposterior and axillary lateral radio-graphs of the shoulder were measured postoperatively. the functional outcome was evaluated with a constant-murley (cm) evaluation. the cm score is a validated shoulder-specific scoring system in which patients report subjective findings. the physician reported the objective measurements of the shoulder. results: follow-ups were completed for all of the patients. the overall complication rate was 3 5.9%,with screw penetration into the gleno humeral joint as the most frequent problem (7.6%). deep wound infections were observed in 2(1%) of the cases and avascular necrosis in 2(1%). all complications occurred in 4-part fractures. subacromial impingement,frozen shoulder,rotator cuff rupture,and wound dehiscence were observed in 2(1%),2(1%),1(6%),and 1(6%) of the cases,respectively. multivariate linear regression analysis revealed that the fracture pattern and the presence or absence of medial support were significant predictors of functional outcome (p=0.026 and p=0.003,respectively). patient age (p=0.58 1),sex (p=0.325),and initial tuberosity displacement (varus/extension or valgus/impaction; p= 0.059) were not significantly associated with the cm score. conclusions: the lphp seems to be a promising implant for the fixation of proximal humerus fractures. however,there are certain limitations that should be mentioned. the number of cases in our study was small,and no safe conclusions can be extracted regarding the rate of avascular necrosis. additional studies with larger cohorts and longer follow-ups are necessary to better define the appropriate indications for and expected outcomes of this technology.
کلیدواژه Humerus fracture; Locking; Plate
آدرس department of orthopedic surg.,patel hospital, Pakistan, indus hospital, Pakistan, civil hospital, Pakistan
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved