   Geometrical uncertainty margins in 3D conformal radiotherapy in the pediatric age group  
   
نویسنده eldebawy e. ,attalla e. ,eldesoky i. ,zaghloul m.s.
منبع journal of the egyptian national cancer institute - 2011 - دوره : 23 - شماره : 2 - صفحه:55 -60
چکیده    Purpose: to evaluate set-up variation of pediatric patients undergoing 3d conformal radiotherapy (3dcrt) using electronic portal image device (epid),in an effort to evaluate the adequacy of the planning target volume (ptv) margin employed for the 3dcrt treatment of pediatric patients. materials and methods: set-up data was collected from 48 pediatric patients treated with 3dcrtfor head and neck (31 patients),abdomino-pelvic (9 patients) and chest (8 patients) sites during the period between september 2008 and february 2009. a total of 358 images obtained by epid were analyzed. the mean (m) and standard deviation (sd) for systematic and random errors were calculated and the results were analyzed. results: all images were studied in anterior and lateral portals. the systematic errors along longitudinal,lateral and vertical directions in all patients showed an m equal to 1.9,1.6,and 1.6. mm with sd of 1.8,1.4,and 1.8. mm,respectively; (head and neck cases: m equal to 1.5,1.2,and 1.6. mm with sd 1.4,1.2,and 1.8. mm; chest cases: m equal to 2.5,1.8,and 0.8. mm with sd 2.7,1.7,and 1.2. mm,abdomino-pelvic cases: m equal to 2.9,2.8 and 2.3. mm with sd 1.6,1.2,and 2.3. mm). similarly,the random errors for all patients showed sd of 1.9,1.6,and 1.8. mm,respectively (head and neck cases: sd 1.7,1.3,and 1.5. mm; chest cases: sd 1.2,1.9,and 2.5. mm; abdomino-pelvic cases sd 2.5,2,and 2.4. mm,respectively). using van herk's formula the suggested (ptv) margin around the clinical target volume (ctv) of 5.5. mm appears to be adequate. conclusion: the ranges of set-up errors are site specific and depends on many factors. © 2011.
کلیدواژه Portal imaging; Radiotherapy setup verification; Random error; Setup uncertainty errors; Systematic error
آدرس radiation oncology department,children's cancer hospital egypt (cche),egypt,national cancer institute,cairo university, Egypt, radiation oncology department,children's cancer hospital egypt (cche),egypt,national cancer institute,cairo university, Egypt, radiation oncology department,children's cancer hospital egypt (cche),egypt,national cancer institute,cairo university, Egypt, radiation oncology department,children's cancer hospital egypt (cche),egypt,national cancer institute,cairo university, Egypt
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved