Temperature-corrected oxygen detection based on multi-mode diode laser correlation spectroscopy
|
|
|
|
|
نویسنده
|
lou x. ,somesfalean g. ,zhang z. ,wu s.
|
منبع
|
journal of spectroscopy - 2013 - دوره : 2013 - - کد همایش:
|
چکیده
|
Temperature-corrected oxygen measurements were performed by using multi-mode diode laser correlation spectroscopy at temperatures ranging between 300 and 473 k. the experiments simulate in situ monitoring of oxygen in coal-combustion exhaust gases at the tail of the flue. a linear relationship with a correlation coefficient of -0.999 was found between the evaluated concentration and the gas temperature. temperature effects were either auto-corrected by keeping the reference gas at the same conditions as the sample gas,or rectified by using a predetermined effective temperature-correction coefficient calibrated for a range of absorption wavelengths. relative standard deviations of the temperature-corrected oxygen concentrations obtained by different schemes and at various temperatures were estimated,yielding a measurement precision of 0.6%. © 2013 xiutao lou et al.
|
|
|
آدرس
|
department of physics,harbin institute of technology,harbin 150001,china,institute of combustion engineering,harbin institute of technology, China, department of physics,lund university,lund 22100,sweden,joint research center of photonics,zhejiang university-royal institute of technology,lund university, China, department of physics,harbin institute of technology, China, institute of combustion engineering,harbin institute of technology, China
|
|
|
|
|
|
|
|
|
|
|
|
|
|