Fa   |   Ar   |   En
   Extraocular surgical approach for placement of subretinal implants in blind patients: Lessons from cochlear-implants  
   
نویسنده koitschev a. ,stingl k. ,bartz-schmidt k.u. ,braun a. ,gekeler f. ,greppmaier u. ,sachs h. ,peters t. ,wilhelm b. ,zrenner e. ,besch d.
منبع journal of ophthalmology - 2015 - دوره : 2015 - شماره : 0
چکیده    In hereditary retinal diseases photoreceptors progressively degenerate,often causing blindness without therapy being available. newly developed subretinal implants can substitute functions of photoreceptors. retina implant extraocular surgical technique relies strongly on cochlear-implant know-how. however,a completely new surgical approach providing safe handling of the photosensor array had to be developed. the retina implant alpha ims consisting of a subretinal microphotodiode array and cable linked to a cochlear-implant-like ceramic housing was introduced via a retroauricular incision through a subperiosteal tunnel above the zygoma into the orbit using a specially designed trocar. implant housing was fixed in a bony bed within a tight subperiosteal pocket in all patients. primary outcomes were patient short term safety as well as effectiveness. nine patients participated in the first part of the multicenter trial and received the subretinal visual implant in one eye. in all cases microphotodiode array pull-through procedure and stable positioning were possible without affecting the device function. no intraoperative complications were encountered. the minimally invasive suprazygomatic tunneling technique for the sensor unit as well as a subperiosteal pocket fixation of the implant housing provides a safe extraocular implantation approach of a subretinal device with a transcutaneous extracorporeal power supply. © 2015 assen koitschev et al.
آدرس klinikum stuttgart-olgahospital,orl-department,pediatric otorhinolaryngology and otology,kriegsbergstraße 62, Germany, center for ophthalmology,university of tübingen,schleichstraße 12-16, Germany, center for ophthalmology,university of tübingen,schleichstraße 12-16, Germany, retina implant ag,gerhard-kindler-straße 8, Germany, center for ophthalmology,university of tübingen,schleichstraße 12-16,tübingen,germany,klinikum stuttgart-katharinenhospital,eye clinic,kriegsbergstraße 60, Germany, retina implant ag,gerhard-kindler-straße 8, Germany, klinikum dresden friedrichstadt,university teaching hospital,eye clinic,friedrichstraße 41, Germany, stz eyetrial,center for ophthalmology,university of tübingen,schleichstraße 12-16, Germany, stz eyetrial,center for ophthalmology,university of tübingen,schleichstraße 12-16, Germany, center for ophthalmology,university of tübingen,schleichstraße 12-16,tübingen,germany,werner reichardt centre for integrative neuroscience (cin),otfried-müller-straße 25, Germany, center for ophthalmology,university of tübingen,schleichstraße 12-16, Germany
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved