>
Fa   |   Ar   |   En
   Repeatability and Reproducibility of Intraocular Pressure and Dynamic Corneal Response Parameters Assessed by the Corvis ST  
   
نویسنده lopes b.t. ,roberts c.j. ,elsheikh a. ,vinciguerra r. ,vinciguerra p. ,reisdorf s. ,berger s. ,koprowski r. ,ambrósio r.
منبع journal of ophthalmology - 2017 - دوره : 2017 - شماره : 0
چکیده    Purpose. to assess the repeatability and reproducibility of dynamic corneal response parameters measured by the corvis st (oculus,wetzlar,germany). methods. one eye randomly selected from 32 healthy volunteers was examined by the corvis st. three different devices were used in an alternated random order for taking three measurements at each device in each subject. standard intraocular pressure (iop),the biomechanical-compensated iop (biop),and dcr parameters were evaluated. the within-subject standard deviation (ζw) and coefficient of variation (cv) were assessed. results. regarding pressure indices,the ζw was below 1 mmhg for repeatability (0.98 for iop and 0.89 for biop) and the cv was 6.6% for iop and 6.1% for biop. for reproducibility,the ζw was around 1 mmhg (1.12 for iop and 1.05 for biop) and the cv was 7.6% for iop and 7.1% for biop. most of dcr indices presented cv for repeatability below 4%. for reproducibility,the cv of most of the indices were below 6%. the deformation amplitude (da) ratio in 1 mm and integrated radius were below 4% (1.2% and 3.8%,resp.). conclusions. the corvis st showed good precision (repeatability and reproducibility) for iop measurements and for dcr in healthy eyes. © 2017 bernardo t. lopes et al.
آدرس rio de janeiro corneal tomography and biomechanics study group,rio de janeiro,rj,brazil,department of ophthalmology,federal university of são paulo,são paulo,sp, Brazil, department of ophthalmology and visual science,ohio state university,columbus,oh,united states,department of biomedical engineering,ohio state university,columbus,oh, United States, school of engineering,university of liverpool,liverpool, United Kingdom, department of surgical sciences,division of ophthalmology,university of insubria,varese, Italy, eye center,humanitas clinical and research center,via manzoni 56,rozzano,italy,humanitas university,via manzoni 56,rozzano,italy,vincieye clinic,milan, Italy, oculus optikgeräte gmbh,wetzlar, Germany, oculus optikgeräte gmbh,wetzlar, Germany, department of biomedical computer systems,faculty of computer science and materials science,institute of computer science,university of silesia,bedzinska 39,sosnowiec, Poland, jr.,rio de janeiro corneal tomography and biomechanics study group,rio de janeiro,rj,brazil,department of ophthalmology,federal university of são paulo,são paulo,sp, Brazil
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved