A New Open Loop Approach for Identifying the Initial Rotor Position of a Permanent Magnet Synchronous Motor
|
|
|
|
|
نویسنده
|
zhu q. ,xiong l. ,liu h. ,zhu y. ,zhang g.
|
منبع
|
journal of control science and engineering - 2017 - دوره : 2017 - شماره : 0
|
چکیده
|
The precision of initial rotor position detection is critical for the start and running performance of permanent magnet synchronous motor (pmsm). this work describes a new open loop approach for identifying the initial position of a pmsm with an incremental encoder,even when a constant load torque is being applied. by giving a testing current with high frequency to the stator winding,the initial rotor position of a pmsm can be detected with reasonable accuracy. the rotor almost does not move during the process of identification. the fft algorithms are used to remove the phase bias effects in identification. our approach is quicker and simpler than the conventional approaches. © 2017 qixin zhu et al.
|
|
|
آدرس
|
school of mechanical engineering,suzhou university of science and technology,suzhou,china,school of electrical and automation engineering,east china jiaotong university,nanchang, China, school of electrical and automation engineering,east china jiaotong university,nanchang, China, school of mechanical engineering,suzhou university of science and technology,suzhou, China, school of mechanical and electronic engineering,jingdezhen ceramic institute,jingdezhen, China, shenzhen han's motor technology company limited,shenzhen, China
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|