   relationship between the filter type and blood flow rate and, dialysis adequacy in hemodialysis patients  
   
نویسنده nezami ghale noee mohsen ,hasani jalil ,erfanpoor saeed ,jafari hedayat
منبع journal of nursing and midwifery sciences - 2020 - دوره : 7 - شماره : 2 - صفحه:94 -98
چکیده    Context: one of the main factors associated with the death of chronic renal failure patients is dialysis adequacy. aims: the present study aimed to investigate the relationship between filter type and blood flow rate with dialysis adequacy in hemodialysis patients referring to educational hospitals of mazandaran university of medical sciences in 2016. setting and design: this correlational study was performed in 2016 in educational hospitals of mazandaran university of medical sciences. materials and methods: this study was performed on 185 hemodialysis patients. sampling was done using simple random sampling. the inclusion criteria included at least 6 months of hemodialysis history and two sessions of dialysis per week. demographic data, as well as information on the filter type and blood flow rate, were collected using a questionnaire. dialysis adequacy is generally measurable by two methods of urea reduction ratio (urr) and k or urea clearance, t or time of dialysis, and v, or volume of urea distribution in the body (kt/v) (k or urea clearance). statistical analysis used: data were described with mean, standard deviation, and frequency and analyzedusing chi‑square and fisher’s exact tests. results: out of a total of 185 patients, 101 patients were male and 84 were female, with a mean age of 57.2 ± 0.7 years. the dialysis adequacy in high‑flux and low‑flux filters was, respectively, 79% and 1.5% based on the kt/v index and 70.6% and 0% according to the urr index. a statistically significant relationship was found between the filter type and blood flow rate with both kt/v and urr criteria (p < 0.001). conclusion: it is recommended to use high‑flux filters with high blood flow rate to improve dialysis adequacy in patients with hemodialysis. however, other factors affecting dialysis adequacy should be considered.
کلیدواژه blood flow rate ,dialysis adequacy ,filter type ,hemodialysis patients
آدرس mazandaran university of medical sciences, school of nursing and midwifery, department of medical surgical nursing, iran, torbat jam faculty of medical sciences, student research committee, iran, gonabad university of medical sciences, social determinants of health research center, faculty of medicine, department of social medicine, iran, mazandaran university of medical sciences, traditional and complementary medicine research center, department of medical surgical nursing, iran
پست الکترونیکی hedayat2003@yahoo.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved