COD AND COLOR REMOVAL FROM WASTEWATERS: OPTIMIZATION OF FENTON PROCESS
|
|
|
|
|
نویسنده
|
GÜNEŞ Elçin ,CİHAN Mehmet Timur
|
منبع
|
pamukkale university journal of engineering sciences - 2015 - دوره : 21 - شماره : 6 - صفحه:239 -247
|
چکیده
|
In this study, cod and color removal from wastewaters by fenton’s oxidation were investigated. in the study the response variables of y1 and y2 were selected as cod removal rate (%) and color removal rate(%), and efficacy variables of a, b, anc c were selected as h2o2 concentration (mmol/l), reaction time (h) and h2o2/fe^2+. the experimental design was used as a two-level factorial design. in the corner points 2³ = 8, in the center points 3 and a total of 3.(8+3)=33 experiments were conducted. effect of h2o2 concentration (mmol/l), reaction time (h) and h2o2/fe^2+ molar ratio on cod removal rate and color removal rate were investigated. the optimum conditions for maximum cod removal rate and color removal rate were at h2o2 concentration 8 mmol/l, reaction time 3 h and h2o2/fe^2+ molar ratio 2.6. at optimum conditions 82% cod removal rate and 93% color removal rate were achieved.
|
کلیدواژه
|
Fenton ,Response surface methodology ,Optimization
|
آدرس
|
Namık Kemal Üniversitesi, Çorlu Mühendislik Fakültesi, Çevre Mühendisliği Bölümü, Türkiye, Namık Kemal Üniversitesi, Çorlu Mühendislik Fakültesi, İnşaat Mühendisliği Bölümü, Türkiye
|
پست الکترونیکی
|
mehmetcihan@nku.edu.tr
|
|
|
|
|
|
|
|
|
|
|
|