Experimental investigation of effectiveness of heating tube with conical baffles
|
|
|
|
|
نویسنده
|
yakar gülay
|
منبع
|
pamukkale university journal of engineering sciences - 2017 - دوره : 23 - شماره : 4 - صفحه:378 -382
|
چکیده
|
In this paper, effectiveness of heated tube with conical baffles was studied experimentally as a function of various inclination angles. by using inclined conical baffles vortex of the flow was increased thereby giving rise to heat transfer and the best inclination angle was determined. experiments were performed for three different inclination angles (45°, 60° ve 80°). water as hot fluid and air as cold fluid were used as working fluids in the experiments. water temperature was fixed as 65 °c. air flow velocities were taken at 8 distinct levels between 2-20 m/s. the results indicated that for ntu>1, 45° and 80° were more effective compared to 60°. in addition for ntu<1, all three angles were found to be similarly effective.
|
کلیدواژه
|
Effectiveness ,Conical baffle ,Inclination angle
|
آدرس
|
pamukkale üniversitesi, mühendislik fakültesi, makine mühendisliği bölümü, Türkiye
|
پست الکترونیکی
|
gyakar@pau.edu.tr
|
|
|
|
|
|
|
|
|
|
|
|