Biomechanical Properties of Glass Ionomer Cement Used for Repair of Incudostapedial Joint Discontinuity
|
|
|
|
|
نویسنده
|
ÜNAL Ahmet ,BEKEM Aylin ,ARAZ SERVER Ela ,ALKAN Zeynep ,YİĞİT Özgür
|
منبع
|
journal of natural and applied sciences - 2014 - دوره : 18 - شماره : 3 - صفحه:152 -156
|
چکیده
|
In this study, the biomechanical properties of glass ionomer cement used for repair of incudostapedial joint bridge in ear in two different distances was investigated. a master block was used to locate the incus and stapes with a 91 degree angle constant. two experimental groups were composed according to the distances between incus and stapes which were adjusted as 1.0 and 2.0 mm. the mixture of bone cement was applied to the gap between incus and stapes and adhere them together. compression tests were performed to these joints. strength value of group 1 were found significantly higher than group 2 (p=0.042). the fragility of bone cement used in 2 mm gap was 25,5% higher compared to 1 mm gap.
|
کلیدواژه
|
Glass ionomer cement. Incus. Stapes. Compression. Fragility.
|
آدرس
|
Yıldız Teknik Üniversitesi, Kimya-Metalurji Fakültesi, Metalurji ve Malzeme Müh Böl , Turkey, Yıldız Teknik Üniversitesi, Kimya-Metalurji Fakültesi, Metalurji ve Malzeme Müh Böl , Turkey, İstanbul Eğitim ve Araştırma Hastanesi, Otolarengoloji ve Baş Boyun Cerrahisi 2 Bölümü, Turkey, İstanbul Eğitim ve Araştırma Hastanesi, Otolarengoloji ve Baş Boyun Cerrahisi 2 Bölümü, Turkey, İstanbul Eğitim ve Araştırma Hastanesi, Otolarengoloji ve Baş Boyun Cerrahisi 2 Bölümü, Turkey
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|