>
Fa   |   Ar   |   En
   Comparison of Ultrasonography and Radiography in Detection of Thoracic Bone Fractures; A Systematic Review and Meta-Analysis  
   
نویسنده Yousefifard Mahmoud ,Baikpour Masoud ,Ghelichkhani Parisa ,Asady Hadi ,Darafarin Abolfazl ,Amini Esfahani Mohammad Reza ,Hosseini Mostafa ,Yaseri Mehdi ,Safari Saeed
منبع Archives Of Academic Emergency Medicine - 2016 - دوره : 4 - شماره : 2 - صفحه:55 -64
چکیده    Introduction: the potential benefit of ultrasonography for detection of thoracic bone fractures has been proven in various surveys but no comprehensive conclusion has been drawn yet; therefore, the present study aimed to conduct a thorough meta-analytic systematic review on this subject. methods: two reviewers independently car-ried out a comprehensive systematic search in medline, embase, isi web of knowledge, scopus, cochrane library, and proquest databases. data were summarized as true positive, false positive, true negative and false negative and were analyzed via stata 11.0 software using a mixed-effects binary regression model. sources of heterogene-ity were further assessed through subgroup analysis. results: data on 1667 patients (807 subjects with and 860 cases without thoracic fractures), whose age ranged from 0 to 92 years, were extracted from 17 surveys. pooled sensitivity and specificity of ultrasonography in detection of thoracic bone fractures were 0.97 (95% ci: 0.90-0.99; i2= 88.88, p<0.001) and 0.94 (95% ci: 0.86-0.97; i2= 71.97, p<0.001), respectively. the same measures for chest radiography were found to be 0.77 (95% ci: 0.56-0.90; i2= 97.76, p<0.001) and 1.0 (95% ci: 0.91-1.00; i2= 97.24, p<0.001), respectively. the sensitivity of ultrasonography was higher in detection of rib fractures, compared to fractures of sternum or clavicle (97% vs. 91%). moreover, the sensitivity was found to be higher when the proce-dure was carried out by a radiologist in comparison to an emergency medicine specialist (96% vs. 90%). conclu-sion: base on the findings of the present meta-analysis, screening performance characteristic of ultrasonography in detection of thoracic bone fractures was found to be higher than radiography. however, these characteristics were more prominent in detection of rib fractures and in cases where was performed by a radiologist.
کلیدواژه Thoracic Fractures; Ultrasonography; Radiography; Diagnostic Tests ,Routine
آدرس Tehran University Of Medical Sciences Tums, School Of Medicine, Department Of Physiology, ایران, Tehran University Of Medical Sciences Tums, School Of Medicine, Department Of Medicine, ایران, Tehran University Of Medical Sciences Tums, School Of Nursing And Midwifery, Department Of Intensive Care Nursing, ایران, Tehran University Of Medical Sciences Tums, Faculty Of Public Health, Department Of Occupational Health Engineering, ایران, Shahid Beheshti University Of Medical Sciences, Shohadaye Tajrish Hospital, Department Of Emergency Medicine, ایران, Shahid Beheshti University Of Medical Sciences, Shohadaye Tajrish Hospital, Department Of Emergency Medicine, ایران, Tehran University Of Medical Sciences Tums, Sina Trauma And Surgery Research Center, School Of Public Health, Department Of Epidemiology And Biostatistics, ایران, Tehran University Of Medical Sciences Tums, Sina Trauma And Surgery Research Center, ایران, Shahid Beheshti University Of Medical Sciences, Shohadaye Tajrish Hospital, Department Of Emergency Medicine, ایران
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved