Fa   |   Ar   |   En
   effect of physical and chemical sterilization on the fracture resistance of orthodontic mini-implants: an in-vitro study  
   
نویسنده johnson sherin ,begum sameena ,laxmikanth sm ,chunduri raghunandan ,riyaz khadeer ,varughese anju
منبع iranian journal of orthodontics - 2023 - دوره : 18 - شماره : 2 - صفحه:1 -8
چکیده    Aim: this study evaluated the effect of physical and chemical sterilization techniques on the fracture resistance of mini-implants. methods: thirty-two titanium mini-implants of 1.5 x 8 mm were randomly divided into four groups: control, steam sterilized, dry heat sterilized, and chemically sterilized. the samples were then tested in the air for fracture resistance using a universal testing machine. a tangential load was applied to the head of the mini-implant with a 1 mm/min crosshead speed after blocking each of them in the machine. also, the maximum load was recorded previous to screw fracture. he kruskal-wallis test and mann-whitney post hoc test were used for data analysis. results: the results of this study demonstrated the mean fracture resistance difference between the four groups was statistically significant at p<0.001. moreover it was showed the control group had significantly higher mean fracture resistance compared to dry heat and chemically sterilized groups at p=0.001 and p=0.009 respectively. this was followed by the stem sterilized group demonstrating significantly higher mean fracture resistance as compared to dry heat and chemically sterilized groups at p=0.001 and p=0.01 respectively. later, the chemically sterilized group also showed significantly higher mean fracture resistance as compared to the dry heat group at p=0.002. however, no significant difference was observed between the control and stem sterilized groups (p=0.29). conclusion: the steam sterilized group demonstrated the highest fracture resistance that was followed by the chemically sterilized group, and the least with the dry heat sterilized group.
کلیدواژه fracture resistance ,mini-implants ,orthodontics ,sterilization ,temporary anchorage devices
آدرس oxford dental college, department of orthodontics and dentofacial orthopaedics, india, oxford dental college, department of orthodontics and dentofacial orthopaedics, india, oxford dental college, department of orthodontics and dentofacial orthopaedics, india, oxford dental college, department of orthodontics and dentofacial orthopaedics, india, oxford dental college, department of orthodontics and dentofacial orthopaedics, india, oxford dental college, department of orthodontics and dentofacial orthopaedics, india
پست الکترونیکی m_anju83@yahoo.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center