>
Fa   |   Ar   |   En
   MICROHYBRID AND FLOWABLE MICROHYBRID DENTAL RESIN COMPOSITES MEASURED IN FRACTURE TOUGHNESS  
   
نویسنده Indrani Decky J. ,Soufyan Andi ,Chairunnisa RR
منبع journal of dentistry indonesia - 2009 - دوره : 16 - شماره : 1 - صفحه:53 -57
چکیده    Flowable microhyrid resin composites. methods. test specimens (30x15x2)mm made of a microhybrid and a flowable microhybrid were prepared in a double torsion mould and were then polymerized for 20 seconds using a light-curing device. taken out from the mould, the specimens were than soaked in disfilled water (37°c) for 1 hour and then fractured in a double-torsion technique. t-test was used to test significance difference between the microhybrid and flowable microhybrid resin composites. result. the use of double-torsion technique resulted in crack initition and crack arrest which revealed klc of 1.14 mn/m^3/2 and 1.045 mn/m^3/2 for the microhybrid and the flowable microhybrid resin composites, respectively. both resin composites were insignificantly different in the fracture toughness values showed by t–test. conclusions. the present study suggested that there was no significant difference between the microhybrid and the flowable microhybrid resin composites tested. it appreared that filler fraction might not affect the fracture toughness of the resin composties tested.
کلیدواژه fracture toughness ,microhybrid composite ,flowable composite
آدرس university of indonesia, Faculty of Dentistry, Department of Dental Materials Science, Indonesia, university of indonesia, Faculty of Dentistry, Department of Dental Material Science, Indonesia, university of indonesia, Faculty of Dentistry, Department of Dental Materials Science, Indonesia
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved