effect of post-reconstruction gaussian filtering on image quality and myocardial blood flow measurement with n-13 ammonia pet
|
|
|
|
|
نویسنده
|
kim hyeon sik ,cho sang-geon ,kim ju han ,kwon seong young ,lee byeongil ,bom hee-seung
|
منبع
|
asia oceania journal of nuclear medicine and biology - 2014 - دوره : 2 - شماره : 2 - صفحه:104 -110
|
چکیده
|
Objective(s): in order to evaluate the effect of post‐reconstruction gaussian filtering on image quality and myocardial blood flow (mbf) measurement by dynamic n‐13 ammonia positron emission tomography (pet), we compared various reconstruction and filtering methods with image characteristics. methods: dynamic pet images of three patients with coronary artery disease (malefemale ratio of 2:1; age: 57, 53, and 76 years) were reconstructed, using filtered back projection (fbp) and ordered subset expectation maximization (osem) methods. osem reconstruction consisted of osem_2i, osem_4i, and osem_6i with 2, 4, and 6 iterations, respectively. the images, reconstructed and filtered by gaussian filters of 5, 10, and 15 mm, were obtained, as well as non‐filtered images. visual analysis of image quality (iq) was performed using a 3‐grade scoring system by 2 independent readers, blinded to the reconstruction and filtering methods of stress images. then, signal‐tonoise ratio (snr) was calculated by noise and contrast recovery (cr). stress and rest mbf and coronary flow reserve (cfr) were obtained for each method. iq scores, stress and rest mbf, and cfr were compared between the methods, using chi‐square and kruskal‐wallis tests. results: in the visual analysis, iq was significantly higher by 10 mm gaussian filtering, compared to other sizes of filter (p<0.001 for both readers). however, no significant difference of iq was found between fbp and various numbers of iteration in osem (p=0.923 and 0.855 for readers 1 and 2, respectively). snr was significantly higher in 10 mm gaussian filter. there was a significant difference in stress and rest mbf between several vascular territories. however cfr was not significantly different according to various filtering methods. conclusion: post‐reconstruction gaussian filtering with a filter size of 10 mm significantly enhances the iq of n‐13 ammonia pet‐ct, without changing the results of cfr calculation.
|
کلیدواژه
|
gaussian filtering ,myocardial blood flow ,pet image reconstruction
|
آدرس
|
chonnam national university hwasun hospital, department of nuclear medicine, south korea, chonnam national university hospital, department of nuclear medicine, south korea, chonnam national university hospital, department of cardiology, south korea, chonnam national university hwasun hospital, department of nuclear medicine, south korea, korea photonics technology institute, south korea, chonnam national university hwasun hospital, department of nuclear medicine, south korea
|
پست الکترونیکی
|
henryhsbom@gmail.com
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|