Fa   |   Ar   |   En
   effects of prosthesis shape and material on the contact mechanics of elbow joints following radial head arthroplasty: an in-silico investigation  
   
نویسنده naghdbishi faezeh ,ghouchani azadeh ,safshekan farzaneh ,ghayyad kassem ,kachooei amir r.
منبع the archives of bone and joint surgery - 2025 - دوره : 13 - شماره : 8 - صفحه:497 -508
چکیده    Objectives: radial head fractures often require prosthetic replacement, but post-surgical complications like radial neck osteolysis, capitellum osteopenia, and ulnohumeral osteoarthritis can arise due to altered elbow biomechanics. this study used the finite element method to evaluate how radial head prostheses (rhps) shape and material affect elbow joint biomechanics.methods: a 3d elbow model was developed, including bones, ligaments, and cartilage. implants featuring two geometries (anatomical vs. axisymmetric) and three materials (polymethylmethacrylate [pmma], polyether ether ketone [peek], and cobalt) were tested. bones were considered isotropic and heterogeneous, ligaments and implants linear elastic, and cartilages were considered hyperplastic materials. stress distributions, contact stresses, and contact areas were assessed during elbow flexion and forearm rotation.results: during forearm rotation, cobalt rhps exhibited lower stresses in the radial neck, indicating higher stress shielding, and all axisymmetric implants showed increased edge loadings. in rotation, only the pmma anatomic rhp showed close contact stresses to the intact model, while all other models resulted in lower stress levels. in flexion, anatomical designs produced more uniform stress distributions in the radial neck that resembled intact conditions and matched intact capitellum contact stresses, in contrast to axisymmetric designs. the reduction in the contact area in the ulnohumeral cartilage was most noticeable with all axisymmetric rhps in flexion.conclusion: the lower contact areas, higher contact stresses, and lower stresses at the radial neck observed in the presence of most axisymmetric rhps and anatomic cobalt rhp can be correlated to postoperative complications. the findings suggest that polymeric anatomical rhps may be superior to conventional metallic axisymmetric options in preserving elbow biomechanics and reducing postoperative complications. however, their long-term effects need to be further explored.        level of evidence: vi
کلیدواژه cobalt ,contact mechanics ,finite element method ,peek ,pmma ,radial head prosthesis
آدرس university of isfahan, faculty of engineering, department of biomedical engineering, iran. , university of isfahan, faculty of engineering, department of biomedical engineering, iran. , ahrar institute of higher education, department of mechanical engineering, iran. , rothman orthopaedics florida at adventhealth, usa. , rothman orthopaedics florida at adventhealth, usa.
پست الکترونیکی arkachooei@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved