>
Fa   |   Ar   |   En
   reliability of center of pressure measures of postural stability in anterior cruciate ligament reconstructed athletes: effect of vibration and cognitive load  
   
نویسنده salavati mahyar ,talebian saeed ,shanbehzadeh sanaz ,keyhani sohrab ,mohseni bandpei mohammad ali ,mohammadi-rad shahrzad
منبع the archives of bone and joint surgery - 2022 - دوره : 10 - شماره : 2 - صفحه:171 -182
چکیده    Background: to evaluate intra and intersession reliability of the center of pressure (cop) parameters in anteriorcruciate ligament reconstructed (aclr) athletes with and without ankle vibration using a dual-task paradigm. methods: postural sway of 14 aclr individuals was assessed during a single-leg stance on a force platform. cop parameters were assessed with manipulating sensory inputs via vision and ankle vibration under single and dual-taskconditions. the outcome variables included cop displacement in medial-lateral (ml) and anterior-posterior (ap) range,mean velocity (mv), and area. during dual-task conditions, the auditory stroop task was applied. intraclass correlationcoefficient (icc) values and standard error of measurement (sem) were assessed for relative and absolute reliability.results: the cop measures had moderate to very high intrasession reliability (icc range: 0.51-0.93) for conditionswith vibration and cognitive task, with the highest iccs for mv and the lowest for area, regardless of eyes being openor closed. the intersession reliability was moderate to high for mv (icc range: 0.60-0.82) and little to very high (iccrange: 0.21-0.97) for the range of ml and ap, as well as an area in conditions with vibration and cognitive task.conclusion: the mv is the most reliable cop parameter for assessing postural control under ankle vibration and dual task conditions for both operated and non-operated sides. during closed-eye conditions, the application of vibration affected the intersession reliability with decreased iccs on the operated side and increased iccs on the non-operatedside.
کلیدواژه anterior cruciate ligament reconstruction ,postural control ,stroop task ,test-retest reliability ,vibration
آدرس university of social welfare and rehabilitation scienceswelfare and rehabilitation sciences, department of physical therapy, iran, tehran university of medical sciencessciences, school of rehabilitation sciencesrehabilitation sciences, department of physical therapy, iran, iran university of medical sciencemedical science, rehabilitation research center, iran, shahid beheshti university of medical sciencesscience, akhtar hospital, iran, university of social welfare and rehabilitation scienceswelfare and rehabilitation sciences, department of physical therapy, iran, university of social welfare and rehabilitation scienceswelfare and rehabilitation sciences, department of physical therapy, iran
پست الکترونیکی shahrzad_rad@rocketmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved