   feasibility analysis of a novel method for theestimation of local bone mechanical properties:a preliminary investigation of different pressure roddesigns on synthetic cancellous bone models  
   
نویسنده brinkmann olaf ,bungartz matthias ,matziolis georg ,maslaris alexander ,zippelius timo ,layher frank
منبع the archives of bone and joint surgery - 2021 - دوره : 9 - شماره : 2 - صفحه:203 -210
چکیده    Background: whilst traumatology around elderly population becomes more and more popular nowadays, the knowledge of local bone quality prior to osteosynthesis is of paramount importance. assessment of the local bone mechanical properties provides essential information related to implant stability and can support treatment strategies in a timely manner. in the acute setting, dual-energy x-ray absorptiometry and quantitative computer tomography cannot be used routinely, and up till now no known intraoperative methods have been established. methods: a novel technique was developed to determine the local bone strength. a feasibility and sensitivity analysis were performed on synthetic cancellous bone models of various densities [including osteoporotic ranges (0.12 - 0.48g/ cm³)] by testing the permeability of different rod probe designs. results: the intraoperative osseomechanical strength measurement (iosm) method revealed high sensitivity for the evaluation of local density on synthetic bone material. among the indenter designs tested, the one with 40° sharp apex and 5 mm diameter reflected accurately the density changes of the synthetic bones. it was also associated with less invasiveness posing no risk for the primary implant stability of the osteosynthesis that may follow. conclusion: the iosm method using the indicated indenter design on synthetic cancellous models appears to be a minimal invasive technique with high accuracy in identifying different bone densities . further studies on human bone material are now focused on the evaluation of the iosm sensitivity compared to the gold standards (dual-energy x-ray absorptiometry and quantitative computer tomography).
کلیدواژه bone mineral density ,implant failure ,intraoperative evaluation ,local bone strength ,osteoporotic fracture ,osteosynthesis
آدرس friedrich-schiller university jena, german center for orthopedics, germany, friedrich-schiller university jena, german center for orthopedics, germany, friedrich-schiller university jena, german center for orthopedics, germany, friedrich-schiller university jena, german center for orthopedics, germany. alfried krupp hospital, department of orthopaedics and trauma surgery, germany, friedrich-schiller university jena, german center for orthopedics, germany, friedrich-schiller university jena, german center for orthopedics, laboratory of biomechanicsbiomechanics, germany
پست الکترونیکی f.layher@waldkliniken-eisenberg.de
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved