>
Fa   |   Ar   |   En
   ultrasound measurements of the ecrb tendon shows remarkable variations in patients with lateral epicondylitis  
   
نویسنده keijsers renée ,koenraadt koen l.m. ,turkenburg jeroen l. ,beumer annechien ,bertram the ,eygendaal denise
منبع the archives of bone and joint surgery - 2020 - دوره : 8 - شماره : 2 - صفحه:168 -172
چکیده    Background: lateral epicondylitis (le) most commonly affects the extensor carpi radialis brevis (ecrb) tendon and patients are generally treated with injection therapy. for optimal positioning of the injection, as well as an estimation of the surface area and content of the ecrb tendon to determine the volume of the injectable needed, it is important to know the exact location of the ecrb in relation to the skin as well as the variation in tendon length and location. the aim of this study was to determine the variation in location and size of the ecrb tendon in patients with le. methods: an observational sonographic evaluation of the ecrb tendon was performed in 40 patients with le. the length of the ecrb tendon, distance from the cutis to the center of the ecrb tendon, the length of the osteotendinous junction at the epicondyle and the distance from cutis to middle of the osteotendinous junction were measured. results: the average tendon length was 1.68cm (range 1.27-1.98; sd 0.177). compared to women, the ecrb tendon of men was on average 0.12cm longer. overall, the average distance from cutis to the center of the ecrb was 0.75cm (range 0.50-1.46cm; sd 0.210), the average length of the junction was 0.55cm (range 0.35-0.87; sd 0.130), and the distance from cutis to middle of the osteotendinous junction was 0.73cm (range 0.40-1.25cm; sd 0.210). conclusion: the size and depth of the ecrb tendon in patients with le is largely variable. while there are no studies yet suggesting sono-guided injection to be superior to that of blind injection, the anatomic variability of this study suggests that the accuracy of injection therapy for le might be compromised when based solely on bony landmarks and therefore not fully reliable. as a result, there is value in further studies exploring the accuracy of the ultrasound guided injection techniques.
کلیدواژه anatomy ,extensor carpi radialis brevis ,lateral epicondylitis ,tennis elbow ,ultrasound
آدرس amphia hospital, department of orthopaedic surgery, upper limb unit, netherlands, amphia hospital, foundation for orthopaedic research, care and education, netherlands, amphia hospital, department of radiology, netherlands, amphia hospital, department of orthopaedic surgery, upper limb unit, netherlands. amsterdam university medical centers, coronel institute of occupational health, netherlands, amphia hospital, department of orthopaedic surgery, upper limb unit, netherlands, amphia hospital, department of orthopaedic surgery, upper limb unit, netherlands. amsterdam university medical centers, department of orthopaedic surgery, netherlands
پست الکترونیکی deygendaal@amphia.nl
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved