Design, Fabrication and Parametric Study of Bulk Current Injection Probe and Its Calibration Fixture
|
|
|
|
|
نویسنده
|
mashriki issa m. ,razavi s.m.j. ,armaki s.h.m.
|
منبع
|
journal of communication engineering - 2020 - دوره : 9 - شماره : 1 - صفحه:93 -108
|
چکیده
|
In this paper, the fabrication of a bulk current injection (bci) probe using two different ferrite materials and a wideband roundedshield calibration fixture or jig used to calibrate bci probe are presented. some optimization ideas are also investigated to increase their performance. the effect of change in various parameters such as slot distance, probe’s shield to probe’s core spacing and the inner surface of probe’s shield on the probe high frequency performance and insertion loss (il) have been studied. results show that increasing the slot distance improves the high frequency response of the probe and increasing the probe’s shield to probe’s core spacing would affect negatively on measured il and decreasing the inner surface of probe’s shield improves the probe working bandwidth.
|
کلیدواژه
|
Bulk current injection (BCI) ,calibration fixture (CF or JIG) ,electromagnetic Compatibility (EMC) ,optimization ,parametric study
|
آدرس
|
high institute for applied science and technology, Syria, malek ashter university of technology, faculty of electrical & computer engineering, Iran, malek ashter university of technology, faculty of electrical & computer engineering, Iran
|
|
|
|
|
|
|
|
|
|
|
|
|
|