improvement of overall efficiency in the gas transmission networks: employing energy recovery systems
|
|
|
|
|
نویسنده
|
safarian sahar ,mousavi maryam
|
منبع
|
gas processing journal - 2015 - دوره : 3 - شماره : 2 - صفحه:1 -24
|
چکیده
|
This study mainly focuses on enhancing the overall efficiency of gas transmission networks. the authors developed a model with detailed characteristics of compressor and pressure reduction stations. following this, they suggested three different systems with gas turbine including: organic rankine cycle (orc), air bottoming cycle (abc), and abc along with steam injection (sia-bc). in addition, use of turbo-expander as a good alternative to the expansion valves was also studied. performance of proposed cycles was investigated on a real case study for natural gas transmission network. results showed that the highest efficiency would be obtained with orc system where n-pentane was used as the working fluid and turbo-expander was considered in pressure reduction stations moreover, the efficiency improvement was estimated to be 22% averagely in comparison with the existing network where the flow was in the span of 50 up to 90 mmscmd.
|
کلیدواژه
|
natural gas transmission network ,organic rankine cycle ,air bottoming cycle ,steam injection air bottoming cycle ,turbo-expander ,overall efficiency
|
آدرس
|
sharif university of technology, department of energy engineering, ایران, sharif university of technology, department of chemical engineering, ایران
|
پست الکترونیکی
|
maryam_mousavi88@yahoo.com
|
|
|
|
|
|
|
|
|
|
|
|