Use of Polyurethane Insulated Panel for Heat Infiltration in Refrigerated Vehicles
|
|
|
|
|
نویسنده
|
oludaisi adekomaya ,sulaiman adedoyin ,kayode adama
|
منبع
|
journal of applied sciences and environmental management - 2017 - دوره : 21 - شماره : 4 - صفحه:703 -706
|
چکیده
|
This study investigates the overall heat transfer coefficient of reinforced composite panel with the aim of being used as the internal and external cover sheet of the insulated panel. the results indicate that the overall heat transfer coefficient, u (w/m^2k) value of the composite reinforced with 10%wt. of fibre at 0◦ orientation (g10e) offers the lowest u value of 0.386950w/m^2k and 0.196680w/m^2k for 50mm and 100mm insulation thicknesses, respectively. this further shows their potential of being used as internal and external cover of insulation materials which may prolong the ageing period of insulation and also the shelf life of fresh raw fruits.
|
کلیدواژه
|
composite sheets ,refrigerated vehicle ,energy conservation ,fossil fuel ,climate change
|
آدرس
|
tshwane university of technology, department of mechanical engineering, mechatronics and industrial design, South Africa, onabanjo university, ibogun campus, faculty of engineering, college of engineering and environmental studies, department of agricultural and mechanical engineering, Nigeria, onabanjo university, faculty of engineering, college of engineering and environmental studies, department of agricultural and mechanical engineering, Nigeria
|
پست الکترونیکی
|
adekomaya.oludaisi@oouagoiwoye.edu.ng
|
|
|
|
|
|
|
|
|
|
|
|
Authors
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|