Fa   |   Ar   |   En
   Assessment of Indoor Radon Levels in Selected Locations within Lagos State University, Ojo, Lagos  
   
نویسنده olaoye m. a. ,aluko t. j. ,jegede o. a. ,agbesi m. f. ,ajayi o. o.
منبع jordan journal of physics - 2017 - دوره : 10 - شماره : 3 - صفحه:139 -141
چکیده    An indoor radon measurement survey was carried out in eleven offices in the campus of lagos state university, ojo, nigeria using pro series 3, radon gas detector model hs71512. the main objective of this survey was to estimate radiation doses received by the dwellers of these offices due to indoor radon exposure. for this research, radon detectors were suspended, where the ventilation slits will not be blocked at least 1.2m above the floor, a height in the breathing zone of a seated person, for 48 hours. the values of indoor concentration vary from 3.70 bq/m^3 to 218.30 bq/m^3 with an average value of 84.04 bq/m^3. the value of effective dose varies from 0.08 msv to 3.76 msv with an average value of 1.45 msv.
کلیدواژه Indoor radon concentration ,Effective dose ,Average effective dose
آدرس lagos state university, department of physics, Nigeria, federal university of agriculture, department of physics, Nigeria, federal university of agriculture, department of physics, Nigeria, lagos state university, department of physics, Nigeria, federal university of agriculture, department of physics, Nigeria
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved