Fa   |   Ar   |   En
   Analysis of Gasketed-Plate Heat Exchanger Performance Using Nanofluid  
   
نویسنده Bozorgan Navid ,Shafahi Maryam
منبع Journal Of Heat And Mass Transfer Research - 2017 - دوره : 4 - شماره : 1 - صفحه:65 -72
چکیده    A numerical analysis of the heat transfer and pressure drop of a water-based γ-al2o3 nanofluid gasketed plate heat exchanger was undertaken to specify its optimum conditions. the results showed that, based on the heat exchanger’s performance index, the optimal volume concentration of γ-al2o3 is approximately 0.016. the heat transfer rate at the optimal concentration of nanofluid is approximately 12.3% higher than that of pure water (base fluid), while the pumping power increased by 1.15%. increasing ϕ values from ϕ=0.016 to ϕ=0.028 will result in a 1% improvement in the heat transfer rate.
کلیدواژه Nanofluid ,Particle Volume Fraction ,Gasketed-Plate Heat Exchanger ,Heat Transfer ,Pressure Drop
آدرس Islamic Azad University, Abadan Branch, Department Of Mechanical Engineering, ایران, California State Polytechnic University, Mechanical Engineering Department, Usa
پست الکترونیکی maryam.shafahi@email.ucr.edu
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center