>
Fa   |   Ar   |   En
   a comparative evaluation of cone-beam computed tomography and multi-slice computed tomography in the diagnosis of sheep mandibular bone defect: an in vitro study  
   
نویسنده moudi ehsan ,haghanifar sina ,kazemian kaveh ,foroughi ramin ,nabahati mehrdad ,bijani ali
منبع caspian journal of dental research - 2018 - دوره : 7 - شماره : 2 - صفحه:24 -29
چکیده    Introduction: diagnosis of lesions and bone defects is very important and there is a lack of substantial studies on the most appropriate method for bone defect measurement. hence, the aim of this study is to evaluate the accuracy of multi-slice computed tomography (msct) and cone-beam computed tomography (cbct) in the diagnosis of mandibular bone defects present in sheep. material & methods: this in vitro study was performed on 15 sheep's mandibular bones. some defects were created in cortical and spongy bone using high-speed hand piece at the buccal and lingual cortical bone of the lower jaw. totally, 75 mandibular bone defects with a depth of 1-3 mm were created. the mandibular bone samples were scanned using msct and cbct scanners, and these scans were evaluated by two oral and maxillofacial radiologists. the positive and negative predictive values, sensitivity and specificity were calculated for both methods. results: the sensitivity of msct and cbct were 78% and 96.5%, and specificity of msct and cbct were 90% and 92% respectively. the positive and negative predictive values were 97.5% and 89.5 % for cbct, and 90% and 92% for msc respectively. the negative and positive likelihood ratios (lr-) and (lr+) were 0.035 and 13.04 for cbct as well as 0.245 and 7.82 for msc respectively. conclusion: the study results demonstrated a higher accuracy of cbct, compared to msct, in the diagnosis of bone defects.
کلیدواژه bone ,cone-beam computed tomography ,diagnosis ,mandible
آدرس babol university of medical sciences, dental materials research center, health research institute, ایران, babol university of medical sciences, dental materials research center, health research institute, ایران, babol university of medical sciences, student research committee, ایران, babol university of medical sciences, oral health research center, health research institute, ایران, babol university of medical sciences, shahid beheshti hospital, clinical research development center, ایران, babol university of medical sciences, social determinants of health research center, health research institute, ایران
پست الکترونیکی alibijani@yahoo.com
 
   مقایسه توموگرافی کامپیوتری با اشعه مخروطی و برش چندگانه در تشخیص نواقص استخوانی ایجاد شده در فک پایین گوسفند: بررسی آزمایشگاهی  
   
Authors موعودی احسان ,حقانی فر سینا ,کاظمیان کاوه ,فروغی رامین ,نباهتی مهرداد ,بیژنی علی
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved