Fa   |   Ar   |   En
   accuracy of digital and conventional intermediate splints used in orthognathic surgery: a triple-blind randomized clinical trial  
   
نویسنده hosseini abrishami majid ,ghadiri moghaddam nafise ,hoseini zarch hosein ,eshghpour majid ,hoseinzadeh melika ,samieirad sahand ,ghaffarian hosseini alireza
منبع journal of dental materials and techniques - 2026 - دوره : 15 - شماره : 1 - صفحه:16 -23
چکیده    Objective: this study compared the accuracy of digitally designed intermediate splints with those fabricated using conventional methods in orthognathic surgery.methods: in this triple-blind randomized clinical trial, 20 patients requiring bimaxillary orthognathic surgery were randomly assigned to receive either digitally designed or conventionally fabricated intermediate splints (n=10). all patients underwent le fort i osteotomy and bilateral sagittal split osteotomy. in the digital group, virtual surgical planning was performed using cone-beam computed tomography (cbct) and intraoral scans to create a three-dimensional model. intermediate splints were then produced using computer-aided design/computer-aided manufacturing (cad/cam) and 3d printing. in the control group, splints were fabricated using conventional model surgery with acrylic resin. to maintain blinding, these splints were subsequently digitized using an intraoral scanner and 3d printed. the primary outcome was surgical accuracy, defined as the absolute difference (mm) between the planned and postoperative maxillary position, measured within 3 days after surgery. secondary outcomes included intraoperative handling, assessed on a 4-point ordinal scale, and fabrication time (hours). the data were analyzed using the independent samples t-test and chi-square test at the significance level of p<0.05.results: the discrepancy between planned and achieved maxillary position was significantly smaller in the digital group (0.70±0.67 mm) compared with the conventional group (1.40±0.84 mm; p=0.044). intraoperative handling and fabrication times did not differ significantly between the groups (p=0.105 and p=0.40, respectively).conclusions: digitally designed intermediate splints demonstrated significantly higher accuracy compared with conventional splints, while fabrication time and intraoperative handling were comparable between the two groups.
کلیدواژه computer-aided design ,computer-assisted surgery ,oral surgery ,orthognathic surgery ,splints ,three-dimensional printing
آدرس mashhad university of medical sciences, mashhad dental school, department of oral and maxillofacial surgery, iran, north khorasan university of medical sciences, bojnurd dental school, department of oral and maxillofacial surgery, iran, mashhad university of medical sciences, oral and maxillofacial diseases research center, iran, mashhad university of medical sciences, mashhad dental school, department of oral and maxillofacial surgery, iran, mashhad university of medical sciences, dental research center, iran, mashhad university of medical sciences, mashhad dental school, department of oral and maxillofacial surgery, iran, mashhad university of medical sciences, student research committee, iran
پست الکترونیکی ghaffarianha4011@gmail.com
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved