Fa   |   Ar   |   En
   Acemetacin and Indomethacin Detection using Modified Carbon Microelectrodes  
   
نویسنده Calado Lénia M. ,Cordas Cristina M. ,Sousa Jo?o P.
منبع analytical and bioanalytical electrochemistry - 2013 - دوره : 5 - شماره : 6 - صفحه:655 -671
چکیده    In the present work, mercury thin film modified carbon microelectrodes were tested towards detection of the pharmacological compounds acemetacin and indomethacin. the compounds were characterized electrochemically by adsorptive stripping differential pulse and square wave voltammetry (adsdpv and adsswv). best results were obtained via adsdpv for both compounds (acemetacin: lod=1.05×10-7 m, loq=3.51×10-7 m; indomethacin: lod=1.34×10-7 m, loq=4.47×10-7 m). these results are comparable to earlier reports using classical hanging drop mercury electrodes, but with environmental advantages due to the limited mercury amount that is used and the easy way to recover it. detection and quantification limits are lower than the obtained with currently used analytical techniques
کلیدواژه Acemetacin ,Indomethacin ,Electroanalytical techniques ,Microelectrodes ,Thin mercury film
آدرس Universidade Nova de Lisboa, REQUIMTE, CQFB/ FCT, Departamento de Qu?mica, Universidade Nova de Lisboa, 2829-516 Caparica, Portugal, Portugal, Universidade Nova de Lisboa, REQUIMTE, CQFB/ FCT, Departamento de Qu?mica, Universidade Nova de Lisboa, 2829-516 Caparica, Portugal, Portugal, Academia Militar, CINAMIL, MDN, Rua Gomes Freire,, Academia Militar, CINAMIL, MDN, Rua Gomes Freire, 1150-244 Lisboa, Portugal, Portugal
پست الکترونیکی joaopsousa1@iol.pt
 
     
   