Quantitative Monitoring of Cobalt Ions by a Co2+ Selective Electrode Based on a calix[4]arene Derivative
|
|
|
|
|
|
|
|
نویسنده
|
Mizani Farhang ,Majdi Marzieh ,Taghvaei-Ganjali Saeed
|
|
منبع
|
analytical and bioanalytical electrochemistry - 2012 - دوره : 4 - شماره : 5 - صفحه:529 -543
|
|
چکیده
|
A highly co2+ ion-selective polyvinyl chloride (pvc) membrane sensor based on aderivative of calix[4]arene (l) as an excellent sensing material is successfully developed. theelectrodes display a nernstian behavior (29.7±0.4 mv decade?1) over wide co2+ ionconcentration ranges from 1.9×10-7 to 1.0×10-1 m with very low limits of detection (8.4×10-8m). the electrodes have a relatively fast response time ( < 50 s), a satisfactory reproducibilityand relatively long life time. the proposed sensor shows a fairly good selectivity toward co2+ion in comparison whit other common cations. the potentiometric responses are independentof the ph of the test solutions in the range of 2.5–8.4. the practical utility of the proposedelectrodes have been demonstrated by their use in potentiometric titration of cobalt withedta. it was also successfully applied in determination of cobalt ions in some aqueoussamples.
|
|
کلیدواژه
|
Co2+ Ion-Selective Electrode ,PVC Membrane ,Calix[4]arene ,Potentiometry ,Sensors
|
|
آدرس
|
payame noor university, Department of Chemistry, Payame Noor University, Iran, ایران, payame noor university, Department of Chemistry, Payame Noor University, Iran, ایران, islamic azad university, Department of Chemistry Islamic Azad University, North Tehran Branch, Tehran, Iran, ایران
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|