Novel Ion Selective Electrode for Determination of Pregabalin in Pharmaceutical Dosage Form and Plasma
|
|
|
|
|
|
|
|
نویسنده
|
Lotfy M. Hayam ,Awad M. Adel ,Shehata A. Mostafa
|
|
منبع
|
analytical and bioanalytical electrochemistry - 2012 - دوره : 4 - شماره : 5 - صفحه:507 -517
|
|
چکیده
|
Ion selective electrode technique was developed for determination of pregabalin.the key to construct such an electrode is to produce a sensitive and selective membrane thatresponds to a particular ionic species. such membrane is usually prepared by in corporatingan appropriate ion exchanger and solvent mediator into a poly (vinyl chloride) or (pvc)membrane matrix. the present work originates from the fact that pregabalin behaves as acation in 0.1 n hcl solution and forms a precipitate with anionic potassium tetrakisp-chlorophenyl borate which used in fabrication of the membrane sensor. the potentiometricresponse was linear with constant slope over a drug concentration range of10-6–10-3 m with slope of 53±1 mv/decade .the developed method was applied successfullyfor the determination of pregabalin in the pure powder form, pharmaceutical formulation andin spiked human plasma without any interference.
|
|
کلیدواژه
|
Pregabalin ,Ion Selective Electrode ,PVC ,Potassium Tetrakis P-Chlorophenyl Borate ,Pharmaceutical Formulation ,Spiked Plasma
|
|
آدرس
|
Cairo University, 1Analytical Chemistry Dept , Faculty of Pharmacy, Cairo University, Egypt, Egypt, Ahram Canadian University, Pharmaceutical Chemistry Dept , Faculty of Pharmacy, Ahram Canadian University, Egypt, Egypt, Cairo University, Analytical Chemistry Dept , Faculty of Pharmacy, Cairo University, Egypt, Egypt
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|