Fa   |   Ar   |   En
   Electrocatalytic Determination of Hydrazine using Glassy Carbon Electrode with Calmagates  
   
نویسنده Mazloum-Ardakani Mohammad ,Sadeghiane Ali ,Moosavizadeh Seyed Hossein ,Karimi Mohammad Ali ,Mashhadizadeh Mohammad Hossein
منبع analytical and bioanalytical electrochemistry - 2009 - دوره : 1 - شماره : 4 - صفحه:224 -238
چکیده    Voltammetric methods were used for the determination of hydrazine andinvestigation of its electrochemical behavior on a glassy carbon electrode in thepresence of calmagite as a homogeneous mediator. the key factors considered in theoptimization process were ph, mediator concentration and scan rate. the results showedwith optimizing ph, mediator concentration and scan rate, the convenient selectivity ofpotential and current of hydrazine oxidation can be achieved. calmagite as a mediatorcan catalyze the hydrazine oxidation in an aqueous buffer solution (ph=8.0). theapparent catalytic rate constant, k and diffusion coefficient, d of hydrazine wereobtained as (1.2×104 m-1s-1) and (4.23×10-5cm2 s-1), respectively. the calibration curvewas linear in the rang of 10.0 – 800.0 ?m hydrazine, and the detection limit was 5.3 ?mby linear sweep voltammetry, also differential pulse voltammetric determination ofhydrazine exhibits two linear range of 1.0-20.0 and 40.0-800.0 ?m and detection limitwas 0.8 ?m.
کلیدواژه Hydrazine ,Electrocatalyst ,Cyclic voltammetry ,Calmagites
آدرس yazd university, ایران, payame noor university, ایران, payame noor university, ایران, payame noor university, ایران, kharazmi university (university of tarbiat moallem), ایران
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved