Prediction of Arterial Blood pH and Partial Pressure of Carbon dioxide from Venous Blood Samples in Patients Receiving Mechanical Ventilation
|
|
|
|
|
نویسنده
|
Tavakol Kamran ,ghahramanpoori bahareh ,fararouei mohammad
|
منبع
|
journal of medical signals and sensors - 2013 - دوره : 3 - شماره : 3 - صفحه:180 -184
|
چکیده
|
Substitution of arterial with venous blood samples to estimate blood gas status is highly preferable due to practical and safetyconcerns. numerous studies support the substitution of arterial by venous blood samples, reporting strong correlations betweenarterial and venous values. this study further investigated the predictive ability of venous blood samples for arterial acid-basebalance (ph) and pressure of carbon dioxide (pco2). participants were 51 post-brain surgery patients receiving mechanicalventilation, who had blood samples taken simultaneously from radial artery of the wrist and elbow vein. results showed significantassociations between arterial and venous ph and pco2. however, the variation of regression residuals was not homogenous, andthe regression line did not fit properly to the data, indicating that simple linear regression is sub?optimal for prediction of arterial ph and pco2 by venous blood sample. although highly significant correlations were found between arterial and venous blood ph and pco2, the results did not support the reliability of prediction of arterial blood ph and pco2 by venous blood samples across a range of concentrations.
|
کلیدواژه
|
Acid base balance ,blood gas analysis ,carbon dioxide ,respiratory insufficiency ,veins
|
آدرس
|
isfahan university of medical sciences, ایران, islamic azad university, ایران, yasuj university of medical sciences, ایران
|
|
|
|
|
|
|
|
|
|
|
|
|
|