>
Fa   |   Ar   |   En
   a feed-forward neural network algorithm to detect Thermal lesions induced by high intensity focused ultrasound in Tissue  
   
نویسنده rangraz parisa ,Behnam Hamid ,Shakhssalim Naser ,Tavakkoli Jahan
منبع journal of medical signals and sensors - 2012 - دوره : 2 - شماره : 4 - صفحه:192 -202
چکیده    Non?invasive ultrasound surgeries such as high intensity focused ultrasound have been developed to treat tumors or to stop bleeding.in this technique, incorporation of a suitable imaging modality to monitor and control the treatments is essential so several imagingmethods such as x?ray, magnetic resonance imaging and ultrasound imaging have been proposed to monitor the induced thermallesions. currently, the only ultrasound imaging technique that is clinically used for monitoring this treatment is standard pulse?echob?mode ultrasound imaging. this paper describes a novel method for detecting high intensity focused ultrasound?induced thermallesions using a feed forward neural?network. this study was carried on in vitro animal tissue samples. backscattered radio frequencysignals were acquired in real?time during treatment in order to detect induced thermal lesions. changes in various tissue propertiesincluding tissue’s attenuation coefficient, integrated backscatter, scaling parameter of nakagami distribution, frequency dependent scatterer amplitudes and tissue vibration derived from the backscattered radio frequency data acquired 10 minutes after treatment regarding to before treatment were used in this study. these estimated parameters were used as features of the neural network.estimated parameters of two sample tissues including two thermal lesions and their segmented b-mode images were used along withthe pathological results as training data for the neural network. the results of the study shows that the trained feed forward neural network could effectively detect thermal lesions in vitro. comparing the estimated size of the thermal lesion (9.6 mm × 8.5 mm) using neural network with the actual size of that from physical examination (10.1 mm  ×  9 mm) shows that we could detect high intensity focused ultrasound thermal lesions with the difference of 0.5 mm × 0.5 mm.
کلیدواژه Feed forward neural network ,high intensity focused ultrasound lesion detection ,Nakagami distribution ,tissue mechanical and acoustical parameters
آدرس islamic azad university, Department of Biomedical Engineering, Science and Research Branch, ایران, iran university of science and technology, School of Electrical Engineering, ایران, shahid beheshti university of medical sciences, Shahid Labbafinejad Medical center, Urology and Nephrology Research Center (UNRC), ایران, Ryerson University, Department of Physics, Canada
پست الکترونیکی jtavakkoli@ryerson.ca
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved