Fa   |   Ar   |   En
   use of flow injection analysis with chemiluminescence detection for determination of sunset yellow (e110) in drink samples  
   
نویسنده hassan media a. ,abdullah narmin s. ,hassan rebwar o. ,majidi behrooz
منبع journal of the iranian chemical society - 2020 - دوره : 17 - شماره : 6 - صفحه:1369 -1375
چکیده    The present study describes a new reversed flow injection chemiluminescence method for the determination of the sunset yellow dye in drink samples. this method is based on the dye’s inhibition effect on the emission of chemiluminescence light (cl) generated from the luminol–h2o2–co(ii) system, in a way that a decrease in cl intensity is proportional to the concentration of the dye. the linear calibration graph is obtained in the range of 0.15–11.0 µg/ml (r2 = 0.9993) and detection limit (lod) = 0.10 µg/ml. the proposed method was applied successfully for the determination of sunset yellow dye in drink samples, and the results are in reasonable agreement when compared with the reported high-performance liquid chromatography method.
کلیدواژه sunset yellow ,chemiluminescence ,flow injection ,drinks analysis
آدرس salahaddin university-erbil, college of science, chemistry department, iraq, salahaddin university-erbil, college of science, chemistry department, iraq, salahaddin university-erbil, college of science, chemistry department, iraq, salahaddin university-erbil, college of science, chemistry department, iraq
 
     
   
Authors
  
 
 

Copyright 2023
Islamic World Science Citation Center
All Rights Reserved